5. Diagnosis
5-12
Festo P.BE-DLP-VSE-... en 0206a
Bit
Explanation for log. “1”
Meaning
6
V
load
Supply voltage for valve solenoid coils < 10 V
7
—
always log. “0”
Fig. 5/13: Octet 8 Device-related diagnosis 1 (diagnostic byte 7)
Structure of device-related diagnosis 2
Bit
Meaning
Explanation for log. “1”
0
Bus-OFF
Measurement bus in Bus-OFF status
1
No reply
No communication with measuring point
2
—
Reserved
3
—
Reserved
4
Error 1
Measuring point cable fracture
5
Error 2
Measuring point
6
Error 3
Measuring point
7
Error 4
Measuring point
Fig. 5/14: Octet 9 Device-related diagnosis 2 (diagnostic byte 8)