A. Technical specifications and index
A-2
Festo P.BE-DLP-VSE-... en 0206a
Electric components
Operating voltage connection
*)
(pin 1 of supply socket)
(not with DLP-VSE-...-ASI)
24 V DC (protected against in-
correct polarity)
-15%/+20% (DC 20.4 ... 28.8 V)
Load voltage connection
*)
(pin 5 of supply socket)
(not with DLP-VSE-...-ASI)
24 V DC (protected against in-
correct polarity)
-15%/+20% (DC 20.4 ... 28.8 V)
Protection against electric
shock
(protection against direct
and indirect contact as per
EN 60204-1/IEC 204)
By connection to a PELV power
unit (Protected Extra-Low Volt-
age)
Indicator light
LED bulb type BA9S
*) the length of the operating voltage cable must not exceed 10 m.
Electromagnetic compatibility
Interference emission
– tested as per EN 55011
– tested as per EN 50081-2
Immunity to interference
– tested as per
EN 61000-4-2...6
– tested as per EN 50082-2
Limit value class A
passed