3. Installation
3-16
Festo P.BE-DLP-VSE-... en 0206a
Setting the diagnostic mode
The following diagnosis can be activated/deactivated with
switch element 8 of the 8-element DIL switch:
S
PROFIBUS-DP device-related diagnosis active/inactive
Diagnosis ON
Diagnosis OFF
Fig. 3/22: Setting the diagnostic mode
If the device-related diagnosis is masked out with switch el-
ement 8, no diagnostic information about the Local control
unit will be sent to the master system, e.g. short circuit at
outputs or undervoltage at the valves (see chapter 5.2).