3. Installation
3-27
Festo P.BE-DLP-VSE-... en 0206a
1
Yellow flat cable
2
Black flat cable
3
Cable socket
4
Cable cap
1
2
3
4
Fig. 3/28: Connecting the AS-i flat cable
Please note with branch lines:
– the maximum total length on the AS-i bus: 100 m.
– the length of the load voltage cable (depends on the cur-
rent consumption of the Local control unit and the fluctu-
ations in the load voltage).
– Fit Festo cable caps ASI-KK-FK or cable sleeves ASI-KT-FK
to open ends of cables. In this way you can avoid leakage
currents and comply with protection class IP65.