4. Commissioning
4-22
Festo P.BE-DLP-VSE-... en 0206a
Sending parametrizing data
The parametrizing data are transmitted from the DP master to
the Local control unit with the function
Set_Prm
.
Octet 1 Station status
Bit
Meaning
Explanation
0
-
Reserved
1
-
2
-
3
WD_On
Response monitoring (watchdog) of the Local control unit on/off:
log. “0”: Off
log. “1”: On
4
Freeze_Req
log. “0”: Freeze mode not requested by master
log. “1”: Freeze mode set by master
5
Sync_Req
log. “0”: Sync mode not requested by master
log. “1”: Sync mode set by master
6
Unlock_Req
Bit 7
Bit 6
Explanation
7
Lock_Req
0
0
min T
SDR
+ slave parameter may be overwritten
0
1
Local control unit for other masters
enabled
1
0
Local control unit for other masters
blocked
1
1
Local control unit for other masters
enabled