5. Diagnosis
5-7
Festo P.BE-DLP-VSE-... en 0206a
Please note
The diagnostic information is only sent to the master sys-
tem when device-related diagnosis is activated in the
switch module. To do this, set switch element 8 of the
8-element DIL switch to “ON”.
When you are commissioning your system, it can in some
cases be useful if you switch off the device-related diagnosis.
If your controller does not start, try the setting “Device-re-
lated diagnosis inactive” on the 8-element DIL switch
(see chapter 3.3.2).
Summary of diagnostic bytes
Diagnostic words
Several diagnostic words are provided for each bus slave.
The diagnostic words and their meanings in conjunction
with the Festo Local control unit are as follows:
Byte*
Octet**
Diagnostic address
Diagnostic address
+ 1
Octet**
Byte*
0
1
Station status 1
Station status 2
2
1
2
3
Station status 3
Master address
(Diag.master_Add)
4
3
4
5
Manufacturer identifica-
tion
(Ident_number
High byte 04)
Manufacturer identifica-
tion
(Ident_number
Low byte 5B)
6
5
6
7
Header
Device-related diag-
nosis 1
8
7
8
9
Device-related diag-
nosis 2
always log. “0”
10
9
Heavy print
= Content will be modified by the Local control unit
*
= Siemens
*
= Siemens
**
= EN50170
Fig. 5/8: Diagnostic words
Summary of Contents for DLP-VSE Series
Page 1: ...Manual Local control unit DLP VSE DLP VSE DP DLP VSE ASI Manual 396 535 en 0206a...
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE DLP VSE en 0206a...
Page 8: ...Contents and general instructions VI Festo P BE DLP VSE en 0206a...
Page 20: ...1 Summary of components 1 8 Festo P BE DLP VSE en 0206a...
Page 54: ...3 Installation 3 30 Festo P BE DLP VSE en 0206a...
Page 84: ...4 Commissioning 4 30 Festo P BE DLP VSE en 0206a...
Page 104: ...5 Diagnosis 5 20 Festo P BE DLP VSE en 0206a...
Page 108: ...A Technical specifications and index A 4 Festo P BE DLP VSE en 0206a...