B
Control via Ethernet (CVE)
168
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
#61
Target speed
System
SINT32
R/-/-/-/-
Current nominal speed
Unit: SINC/s
Values: –2147483648 … 2147483647
Default: 0
#62
Nominal current
System
SINT32
R/-/-/-/-
Current nominal current
Unit: mA
Values: –2147483648 … 2147483647
Default: 0
#63
Setpoint force
System
SINT16
R/-/-/-/-
Current nominal force in one-tenth of one percent of the maximum motor current (calculated from the
nominal current)
Unit: ‰
Values: –32768 … 32767
#70
Actual acceleration
System
SINT32
R/-/-/-/-
Current, calculated actual acceleration
Unit: SINC/s²
Values: –2147483648 … 2147483647
Default: 0
#72
Nominal acceleration
System
SINT32
R/-/-/-/-
Current nominal acceleration
Unit: SINC/s²
Values: –2147483648 … 2147483647
Default: 0
#96
Position deviation
System
SINT32
R/-/-/-/-
Current following error = actual position - setpoint position
Unit: SINC
Values: –2147483648 … 2147483647