5
Commissioning
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
107
Function of inputs and outputs
DIN
Mode 0:Record selection
Mode 1: Jogging and teaching
Pin
1
RECORD
Bit 0…4
Binary addressing of the
set of commands for re
cord selection
è
Record 0 is reserved for
reference travel (homing).
Records 1 .... 31 can be
parameterised.
RECORD
Bit 0…2
Binary addressing of the
set of commands
è
Records 1 .... 7 can be
parameterised.
X1.1
2
X1.2
3
X1.3
4
JOG+
1:
Jog positive
X1.4
5
JOG–
1: Jog negative
X1.5
6
Start
0
è
1: Starts the ad
dressed set of commands
TEACH
0
è
1: Transfer current
position to addressed set
of commands
X1.6
7
PAUSE
0: Actuator stops (inter
mediate stop).
1: With START the ad
dressed record can be
continued.
Optional: delete remain
ing path (DIN11)
Stop
0: Actuator stops
1: JOG+/JOG- can be per
formed.
X1.7
8
MODE
Switch over mode.
0
è
1: mode 1
1
è
0: mode 0
X1.8
9
BRAKE
CONTROL
1: Opens the holding brake via X6.5 (BR+) whenever the closed-loop
control is closed. Makes manual offset of the axis possible. The hold
ing brake remains opened while the 1-signal is present (regardless of
CONTROL ENABLE).
0: Automatic brake control via CONTROL ENABLE (normal operation)
X1.9
10
Control
ENABLE
0
è
1 Requirement for controller enable and automatic opening of
the brake on motor with holding brake
1
è
0
Controlled braking to a stop with the parameterised decelera
tion function (Quick Stop). On motor with holding brake: apply the
brake. Disabling the closed-loop controller.
X1.10
11
RESET
0
è
1: In the event of a malfunction: reset an acknowledgeable error -
or - delete remaining path after PAUSE
X1.11
Tab. 5.11 Binary profile: function of the digital inputs