4
Installation
70
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
The following connections are designed as terminal strips (connectors). The connectors are included in
the scope of delivery (connector assortment NEKM-C-10).
Connection
Grid
[mm]
Wire cross-section
[mm
2
]
Stripping the cable
[mm]
Plug version
[X1A]
3-pin
2.5
0.081 … 0.518
7 … 8
CAGE-AWG20-28
[X2]
8-pin
2.5
0.081 … 0.518
7 … 8
CAGE-AWG20-28
[X3]
5-pin
2.5
0.081 … 0.518
7 … 8
CAGE-AWG20-28
[X6]
6-pin
3.5
0.081 … 1.31
8 … 9
CAGE-AWG16-28
[X9]
5-pin
3.5
0.081 … 1.31
8 … 9
CAGE-AWG16-28
Tab. 4.2
Overview of connectors (accessories)
Connection
Cable length [m]
Cable version
[X1]
I/O
30
[X1A]
Homing Switch
30
[X2]
Encoder
10
[X3]
STO
30
[X6]
motor
10
[X9]
Power supply
30
[X18]
Ethernet
30
1)
This cable is available as an accessory
è
www.festo.com/catalogue.
2)
The cable must be packaged by the customer.
3)
Standard network cable. Applicable for the fieldbus length are the specifications for Ethernet networks according to
ANSI/TIA/EIA-568-B.1.
Tab. 4.3
Cable version