B
Control via Ethernet (CVE)
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
167
#4
Block higher-order control
System
UINT08
R/W1/W2/-/-
0x00
è
The master control is not blocked. The master control can be changed by all interfaces.
0x01
è
The master control is blocked. Before the master control can be changed again, this block
has to be removed again. Only the interface that has the master control at the time can do this.
Values: 0 … 1
Default: 0
#31
Record number preselection
Record
UINT08
R/W1/W2/-/-
Number of the preselected positioning record. At the controller interface, a new positioning record
can already be preselected while an old one is still active. Note: The active positioning record is in
object #141
Record 1 … xx
è
normal records
Values: 1 … 31
#57
Actual speed
System
SINT32
R/-/-/-/-
Current actual velocity
Unit: SINC/s
Values: –2147483648 … 2147483647
Default: 0
#58
Actual current
System
SINT32
R/-/-/-/-
Current motor current
Unit: mA
Values: –2147483648 … 2147483647
Default: 1
#59
Actual force
System
SINT16
R/-/-/-/-
Current actual force in one-tenth of one percent of the maximum motor current (calculated from the
measured current)
Unit: ‰
Values: –32768 … 32767 Default: 0
#60
Setpoint position
System
SINT32
R/-/-/-/-
Current Target Pos.
Unit: SINC
Values: –2147483648 … 2147483647
Default: 0