A
Technical appendix
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
145
A.1.2
Operating and Environmental Conditions
Operating and Environmental Conditions
Ambient temperature
[°C]
0 …+50
Storage temperature
[°C]
–25 …+75
Cooling
Passive
Temperature warning from output stage
Output stage temperature exceeded
[°C]
,
+85 Warning 0x33
Output stage temperature too low
[°C]
.
-15
Warning 0x33
Switch-off temperature for output stage
Output stage temperature exceeded
[°C]
,
+95 error 0x15
Output stage temperature too low
[°C]
.
-25
error 0x16
Degree of protection
IP40 (with full pin allocation)
Air humidity (at 25°C)
[%]
0 …90, non-condensing
Degree of contamination
2 (per EN 50178)
Permissible setup altitude (above sea level)
[m]
2000
Vibration and shock resistance
(in accordance with IEC 60068)
– Vibration (part 2-6)
– Shock (part 2 - 27)
– Continuous shock (part 2 - 27)
Severity level (SL)
for wall or H-rail
mounting
– Wall: SG2; H-rail: SG1
– Wall: SG2; H-rail: SG1
– Wall and H-rail: SG1
1)
Explanation of the severity level
è
Table “Explanation on vibration and shock – severity level”
Explanation on vibration and shock – severity level SL:
Vibration load
Frequency range [Hz]
Acceleration [m/s
2
]
Deflection [mm]
Severity level 1 SL2
SL1
SL2
SL1
SL2
2 … 8
2 … 8
–
–
±3.5
±3.5
8 … 27
8 … 27
10
10
–
–
27 … 58
27 … 60
–
–
±0.15
±0.35
58 … 160
60 … 160
20
50
–
–
160 … 200
160 … 200
10
10
–
–
Shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
SL1
SL2
SL1
SL2
SL1
SL2
±150
±300
11
11
5
5
Continuous shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
±150
6
1000