4
Installation
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
69
4.3
Connections and cables
Caution
Unexpected and unintended movement of the actuator as a result of incorrectly as
sembled cables
Only use the plug connectors provided and preferably the cables listed in the spe
cified accessories (
è
Observe the tightening torques in the documentation of the cables and plugs used.
Lay all flexible cables so that they are free of kinks and mechanical stress; if neces
sary in a drag chain. Observe the instructions for the axis and the additional com
ponents.
ESD protection
At unassigned plug connectors, there is the danger that damage may occur to the
device or to other system parts as a result of ESD (electrostatic discharge).
Observe the handling specifications for electrostatically sensitive devices.
Seal unassigned plug connectors with protective caps.
Earth system parts prior to installation.
Use appropriate ESD equipment (e.g. shoes, earthing straps, etc.).
Note
When mounting the controller outside the control cabinet:
Observe the IP protection class of the controller and the connectors/cables.
Seal unassigned plug connectors with protective caps.
1
[X9] Power supply
2
[X1] I/O (SPC/IPC)
3
[X18] Ethernet
4
[X1A] Reference switch
5
[X3] STO
6
[X2] Encoder
7
[X6] Motor
8
FE function earth (3x)
1
2
3
4 5 6 7 8
Fig. 4.1
Ports