![Festo CMMO-ST-C5-1-DION Original Instructions Manual Download Page 80](http://html1.mh-extra.com/html/festo/cmmo-st-c5-1-dion/cmmo-st-c5-1-dion_original-instructions-manual_2283101080.webp)
5
Commissioning
80
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
5.2
Establish an Ethernet connection
Note
On delivery, the integrated DHCP server (Dynamic Host Configuration Protocol) of the
motor controller is active. The DHCP server enables
direct connection
between the
motor controller and a PC configured individually as a DHCP client.
The factory setting “DHCP Server Active” is generally not suitable for network operation.
In an existing network, there is typically a DHCP server already available. Two active
DHCP servers on a network can lead to network faults.
For initial start-up, connect the motor controller directly to the PC via the Ethernet
interface .
Do
not
connect the motor controller to the network as a DHCP server if another DH
CP server is already enabled on the network.
To integrated in a network, first change the IP configuration of the motor controller
with FCT (
è
Fig. 5.1
Initial start-up via direct connection (point-to-point connection)
Ethernet direct connection
Prerequisites
– The PC is configured as a DHCP client (usually the default setting for PCs).
– The motor controller is configured as a DHCP server (factory setting).
Connection
to be established
1. Connect the Ethernet interface of the motor controller directly to the
Ethernet interface of the PC (point-to-point connection).
2. Switch on power supply to the motor controller.
The DHCP server on the motor controller assigns an IP address to the PC.
That means that a network connection has been established.
Connection
to be tested with the
web server
Call up the website of the web server in the web browser (
è
Chapter 5.3.1)
Connection
Test with FCT
1. Install and start FCT (
è
2. Configure the FCT interface.
3. With FCT menu [Component][Online][Login] establish an online
connection.
Tab. 5.1
Connection of motor controller as active DHCP server (factory setting).