5
Commissioning
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
85
5.3.3
Configuring and parameterising the actuator
Note
To accept a parameter file from the Festo server, enter the complete OMS ID on
the“Parameters” website in accordance with the product labelling. Incomplete entry of
the code may result in malfunctions, uncontrolled behaviour and damage.
Only select the parameter file via OMS-ID for positioning systems (OMS) in delivery
status.
After a modification to the OMS system, e.g. a change in the attachment position of
a motor, perform start-up with FCT.
Adopting the Festo parameter file from the Internet
If an Internet connection is available (via 2nd Ethernet interface or WLAN/WiFi), the required parameter
file from the Festo Parameter Cloud is saved to the PC:
1. Calling“Parameters” website in the web browser
2. Enter the complete OMS-ID under“Parameter upload/download”.
With OMS systems without OMS-ID: enter the complete type code
3. Search for file (Parameter upload/download: <Search>)
4. Save file (Parameter upload/download: <Save>)
Alternatively, you can search for the file in the Festo Support Portal and save it to the PC before the
download
è
www.festo.com/sp, CMMO-ST
Downloading the parameter file (*.fpf )
In a download, the selected parameter file is written to the permanent memory of the motor controller:
1. Enable“Parameters” page, section“Control”,“Device Control”.
2. Select file saved in file system <Browse>.
3. Download file to the controller <Download parameter set to CMMO>.
The parameter file is then saved automatically and in permanent form to the motor controller.