5
Commissioning
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
83
5.3.1
Web server call
Requirements:
– The Ethernet connection between motor controller and PC is established (
è
– Web browser is enabled on the PC (Internet Explorer >6; Firefox >3; JavaScript).
– The power supply to the motor controller is switched on.
Calling the web server:
Fig. 5.2
Call the web server
1. Open the web browser.
2. Enter the IP address of the motor controller in the address row of the browser:
Factory setting: 192.168.178.1.
if required: establish the current IP address (
è
FCT menu [Component][FCT Interface],
<Scan...>).
Then the online connection is established.
After the web browser call, the“Diagnosis” web page is displayed with information
about the actuator connected. The button on the right side of the page effects the
change to the“Parameter” web page.
Once password protection for the motor controller has been enabled, the password
needs to be entered to change pages; the“Username” box in the query dialogue on
the browser can remain empty because it is not evaluated.
è
Chapter 2.3.3, pass
word protection.
Website
Sections
Description
Diagnosis
Status
Status information about the device and identification of
the motor controller (wave function); adjustment to the
dimensional system (unit: mm/inch/inc)
Signal statuses of the digital inputs/outputs
Diagnostic Memory
Readout of the diagnostic memory
Parameters
Parameter Up/Download
Uploading and downloading a parameter file
Status
Status information about a device
Control
Acceptance of device control and controller enable
Password
Password protection
Homing
Carrying out homing
Record Table
Parameterising and testing of sets of commands (valve
profile)
1)
By scrolling, the individual components of the website can be moved into the visible section of the window
2)
Active signals are marked with a blue dot. Inactive signals are marked with a grey dot.
3)
The section is only available for positioning systems (OMS)
Tab. 5.2
Website“Diagnosis” and“Parameters”