5.5.3
Acknowledge error (RESET)
Whenever an error occurs, the motor controller goes into error status (READY=0).
Acknowledgeable
errors (
è
Chapter 6.3.2) can be reset by pressing RESET. If the error cannot be acknowledged, the
controller must be restarted.
In a few cases, acknowledgement is possible immediately, e.g. with a drag error. In other cases, the
troubleshooting must be remedied first (e.g. temperature error, load voltage error).
Shortly after acknowledging the error (RESET 0
è
1) the error is reset. To enable the controller, a rising
flank (CONTROL ENABLE 0
è
1)
is required. After that, the motor controller is once again ready for op
eration (READY=1).
RESET
DIN11
Ready
DOUT10
t
CONTROL ENABLE
DIN10
Faults
No error
1
2
3
Time delay t
2 ms
1
Error event
2
Acknowledge error
3
Request controller enable
Fig. 5.6
Valve profile: acknowledge error