![Festo CMMO-ST-C5-1-DION Original Instructions Manual Download Page 159](http://html1.mh-extra.com/html/festo/cmmo-st-c5-1-dion/cmmo-st-c5-1-dion_original-instructions-manual_2283101159.webp)
B
Control via Ethernet (CVE)
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
159
Description of transitions
Condition for status transition
Description
0
Start
è
Not ready to switch on
This status transition always takes place unconditionally
after a (re)start.
1
Not ready to switch on
è
Switch on disabled
The self test of the logic supply has been completed
successfully. Automatic change of state to Switch on
disabled.
2
Switch on disabled
è
Ready to switch on
CW.
FR
(Error Reset) = 0
CW.
QS
(Quick Stop) = 1
CW.
EV
(Enable Voltage) = 1
CW.
SO
(Switch on) = 0
3
Ready to switch on
è
Switched on
CW.
FR
(Error Reset) = 0
CW.
EO
(Enable Operation) = 0
CW.
QS
(Quick Stop) = 1
CW.
EV
(Enable Voltage) = 1
CW.
SO
(Switch on) = 1
4
Switched on
è
Operation enabled
CW.
FR
(Error Reset) = 0
CW.
EO
(Enable Operation) = 1
CW.
QS
(Quick Stop) = 1
CW.
EV
(Enable Voltage) = 1
CW.
SO
(Switch on) = 1
5
Operation enabled
è
Switched on
CW.
FR
(Error Reset) = 0
CW.
EO
(Enable Operation) = 0
CW.
QS
(Quick Stop) = 1
CW.
EV
(Enable Voltage) = 1
CW.
SO
(Switch on) = 1
6
Switched on
è
Ready to switch on
CW.
FR
(Error Reset) = 0
CW.
QS
(Quick Stop) = 1
CW.
EV
(Enable Voltage) = 1
CW.
SO
(Switch on) = 0
7
Ready to switch on
è
Switch on disabled
CW.
FR
(Error Reset) = 0
CW.
EV
(Enable Voltage) = 0
or:
CW.
FR
(Error Reset) = 0
CW.
QS
(Quick Stop) = 0
CW.
EV
(Enable Voltage) = 1
8
Operation enabled
è
Ready to switch on
CW.
FR
(Error Reset) = 0
CW.
QS
(Quick Stop) = 1
CW.
EV
(Enable Voltage) = 1
CW.
SO
(Switch on) = 0
9
Operation enabled
è
Switch on disabled
CW.
FR
(Error Reset) = 0
CW.
EV
(Enable Voltage) = 0