![Festo CMMO-ST-C5-1-DION Original Instructions Manual Download Page 57](http://html1.mh-extra.com/html/festo/cmmo-st-c5-1-dion/cmmo-st-c5-1-dion_original-instructions-manual_2283101057.webp)
2
Product description
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
57
2.6.3
Record linking
With record linking in binary profile, sets of commands are executed in a specified sequence. In every
record, the number of the next record to be executed is parameterised. As soon as the step enabling
condition is satisfied, the specified subsequent record is started. A record sequence is executed with
the start of a record in the sequence without any further start command, up to the last record in the
sequence. Record linking can be used to implement complex movement sequences, e.g.:
–
Running a speed profile
–
Positioning and clamping in a motion sequence
–
Executing a force profile for pressing procedures.
The linking sequence can be influenced by the following parameters:
Parameters
Description
Condition
(Condition)
Indicates when the subsequent record should be started (step enabling)
è
Start Delay
Waiting time that expires before the record is started from a record
chaining.
MC visible
(MC visible)
Indicates whether the “Motion Complete” signal should occur between the
individual records of a record sequence.
Final Velocity
Final speed at which the record should be completed at the target position.
The final velocity must be less than or equal to the parameterised
maximum speed of the order.
Following Set
(Following Set)
Number of the record that should be started automatically when the
condition is reached
Tab. 2.52 Parameters for influencing the track characteristics
A comparator, by way of example, can be used as a condition. The following conditions are possible:
Condition
The following record is started if ...
Motion Complete
... the signal “Motion Complete” is enabled
Position comparator active
... the current position is in the position window
Speed comparator active
... the speed is within the defined velocity window
Force comparator active
... the force is within the force/torque window
Time comparator active
... the length of time for which order processing is in the time window
Tab. 2.53 Step enabling conditions