2.16.8 INSTALLATION SETTINGS.
Press the
Installation Settings
icon and use the
Installer PIN code to access a screen containing different icons for these settings.
Note: The Installation Settings function is PIN-protected, so that it can only be used by
qualifi ed personnel.
Press the
Installer Settings
option and enter the
Installer PIN
code that, by default, is
4444
and press
OK
to access the screen containing the different icons to confi gure monitor operations and the rest of the
installation.
2.16.8.1 Monitor Settings
The factory default address of the monitor is 10.0.0.1.
- Block: 2 digits (00..99) = block number.
- Floor: 2 digits (00..99)
- Unit number: 4 digits (0000..8191) = number of homes.
- Extension number: 1 digit (0..7) = number of monitors per home.
Note: There must always
be a monitor with extension 0.
This information will automatically generate the IP address of the monitor.
Note: The default address must not be used in real installations, as it could generate IP
address confl icts.
o
SIP Server.
•
End-to-end (left blank by default).
•
SIP Server. Function not available.
o
Server database.
•
IP Address of the Database Server (Property Management Station confi gured during PC
installation as database = Server PC).
o
NTP Server.
•
Not used if left blank.
•
IP address of the NTP server. Function not available.
To access
Monitor Settings,
press
General Settings
to access the screen where the
Installer Settings
option is located (press)
,
enter the
Installer PIN
code, which by default is
4444
and press
OK
to access the screen where the
Monitor Settings
option is located.