Page 12
VIVO Monitor
VIVO Monitor
Monitor address programming. Monitor Settings.
The factory default address of the monitor is 10.0.0.1.
- Block: 2 digits (00..99) = block number.
- Floor: 2 digits (00..99)
- Unit number: 4 digits (0000..8191) = number of homes.
- Extension number: 1 digit (0..7) = number of monitors per home.
Note: There must always
be a monitor with extension 0.
This information will automatically generate the IP address of the monitor.
Note: The default address must not be used in real installations, as it could generate IP
address confl icts.
o
SIP Server.
•
End-to-end (left blank by default).
•
SIP Server. Function not available.
o
Server database.
•
IP Address of the Database Server (Property Management Station confi gured during PC
installation as database = Administrator PC).
o
NTP Server.
•
Not used if left blank.
•
IP address of the NTP server. Function not available.
To access
Monitor Settings,
press
General Settings
to access the screen where the
Installer Settings
option is located (press)
,
enter the
Installer PIN
code, which by default is
4444
and press
OK
to access the screen where the
Monitor Settings
option is located.
- Note: To go back to the Start Menu, press the intui-
tive icons displayed on the monitor - such as arrows
or icons corresponding to the current screen - by
pressing the MENU button or after a period of time,
as the monitor returns to stand-by (screen off) after
30 seconds.