Page 65
VIVO Monitor
VIVO Monitor
SOS
SOS
The corresponding alarm LED indicates the current status. The monitor regularly checks the alarm status
and activates the corresponding LED (HOME, OUT, NIGHT).
Note:
- If no Sensor Module is detected or confi gured, the alarm LED will not light up.
- Should communications fail between the Sensor Module and the monitor, the PMS is informed and the
corresponding LED on the monitor will switch off.
OUT mode
HOME mode
NIGHT mode
SOS
Notes:
- In zones with delayed activation mode, when the security level is increased the system waits 100 seconds
before arming. For example: After changing from Home mode to Out mode, the door can be opened in
order to leave the home without the alarm being triggered for 100 seconds.
- Pre-Alarm Notifi cation. After receiving a pre-alarm command from the Sensor Module, the monitor displays
a keypad to enter the alarm PIN and deactivate the alarm before it is triggered.
When a sensor is activated,
the system offers a pre-alarm time of 40 seconds before sending the alarm.
For example: On entering the
home with the alarm mode set to Out, the system will wait 40 seconds for the alarm mode to be changed
to Home or Night before sending the alarm.
When an alarm is activated, notifi cation is sent to the corresponding Property Management Station (Guard
Unit) Alarm. On receiving an alarm, the Vivo monitor sends it to the Property Management Station Alarm
with the following information: Home number, Sensor Module Address, Zone number and Zone Name (if
defi ned). The monitor will also generate an alarm tone for 300 seconds.