2.5.2.7 ACTIVATING OR DEACTIVATING THE RELAY UPON RECEIVING AN ACTIVATE/
DEACTIVATE COMMAND (receptor relay)
Function description.
The relay can be confi gured to
activate it
when an Activate Relay command is received at
its address, or
deactivate
upon receiving the Deactivate relay command, transmitted by a
remote device.
* First remote device operating mode (transmitter relay):
You can activate or deactivate a
relay
by activating the Set terminal (button connected
between the SET and - terminals), from a remote relay.
For this, the remote relay must be confi gured as described in section:
2.5.1 TX Operating
Mode,
section:
2.5.1.6 ACTIVATE OR DEACTIVATE THE REMOTE RELAY FUNCTION
If the relay we are confi guring activates the Reset terminal (button connected between the
RESET and - terminals), the relay (receptor) is deactivated.
By default, Continued function is deactivated, so upon activating the
Set
terminal, the remote
relay is activated and the
Reset
terminal deactivates the remote relay.
Note: The time confi gured in the transmitter relay does not effect the receptor relay.
* Second remote device operating mode (transmitter relay):
Continued mode. If with a relay in charge of activating the relay (receptor), we activate
Continued mode
see:
2.4 CONFIGURATION OF ACTIVATION TIMES VIA THE INTEGRATED
PUSH BUTTONS (Sec/Single - Min/All)
,
upon activating the Set terminal of the transmitter
relay, the relay is activated (receptor), and if the Set terminal is deactivated or the Reset
terminal on the fi rst transmitter relay is activated, the relay (receptor) is deactivated.
TX
RX
3257
REF.
DISABLE
OUTPUT
12V 0.3A
SEC SINGLE
MIN ALL
OUT
NO
NC
C
RELAY
AV TRES CRUCES, 133
FERMAX ELECTRONICA, SAU
46017 VALENCIA - SPAIN
MADE IN SPAIN
BUS
OUTPUT
C
D
T
RX
PRG
MODULO RELE
DUOX
DUOX RELAY
MODULE
BUS INPUT
B
B
PRG
TX
B B
+12V
-
RESET/
SET
V
ON
3257
REF.
DISABLE
OUTPUT
12V 0.3A
SEC SINGLE
MIN ALL
OUT
NO
NC
C
RELAY
AV TRES CRUCES, 133
FERMAX ELECTRONICA, SAU
46017 VALENCIA - SPAIN
MADE IN SPAIN
BUS
OUTPUT
C
D
T
RX
PRG
MODULO RELE
DUOX
DUOX RELAY
MODULE
BUS INPUT
B
B
PRG
TX
B B
+12V
-
RESET/
SET
V
ON
DESTINATION
receptor relay
ORIGIN
transmitter relay
(confi gured as Activa-
tion or Deactivation
upon RECEIVING an
Activate or Deacti-
vate transmitter relay
command.
Relay
(receptor relay)
(remote relay confi g-
ured as transmitter,
SEND the Activation
or Deactivation com-
mand on relay)
REMOTE relay
(transmitter relay)
Notes:
- This confi guration can not be made using integrated push buttons in the relay (Min/All -
Sec/Single), and must be done via the Duox Programmer, see the corresponding chapter
in Section
“3. CONFIGURATIONS - FUNCTIONS: PROGRAMMING WITH THE DUOX
PROGRAMMER”.