3. CONFIGURATIONS - FUNCTIONS: PROGRAMMING WITH THE DUOX PROGRAMMER
3.1 RESETTING PARAMETERS
The parameter reset for the relay to return to its default values can only be done with the
integrated buttons in the relay itself.
See how this is done in section: 2.1 RESETTING
PARAMETERS.
3.2 CONFIGURING ACTIVATION TIMES
Function description.
Confi guration of activation times.
*
Timed: This allows you to confi gure the activation time between 1 and 120 seconds
in the seconds range and between 1 and 120 minutes in the minute range.
* Continued (TOGGLE): by activating the SET terminal the relay remains permanently
activated until deactivated by the RESET terminal.
Timed Function confi guration.
1. Press the
On/Off
button, the display will show the
DUOX Relay
and
version.
2.
Via the arrows we select the
1.3.TOGGLE MODE
menu and if the
Toggle mode
(Continued):
a) If activated press
Ok.
Via the arrows we select
NO
and press
Ok.
b) If deactivated (
NO
) go directly to point
4.TIMING.
3. Via the arrows we select the
4. TIMING
menu and press
Ok.
4. With the arrows we select the range
(minutes or seconds)
and with the number keys we
confi gure the
time.
Once the desired time is confi gured, press
Ok.
Note:
The time must be less than 120, if a higher number is entered, we are asked again for a
new parameter.
5. Upon turning the programmer off, the time remains confi gured.
CONFIGURATIONS
Continued function confi guration (TOGGLE).
1. Press the
On/Off
button, the display will show the
Duox Relay
and
version.
2. Via the arrows we select the
1.3. TOGGLE MODE
menu and press
Ok.
3. Via the arrows we select
YES
and press
Ok.
4. Upon turning the programmer off, the time remains confi gured.
Important information regarding turning the Programmer on/off:
- The programmer is turn on by pressing theOn/Off button.
- To turn off the programmer, long pressOn/Off for 2 seconds, until the display turns off. If the
programmer is inactive for 1 minute, it displays CONNECTION OFF, and should turn off, as
explained, to be able to use it again.
This is because in the confi guration mode via the Duox Programmer, there is a 60 second
timeout where if no key is pressed on the programmer, the relay returns to standby and the
programmer displays the message CONNECTION OFF.