Page 14
Function confi guration.
1.
Press the
PRG
button, the
C
led should light up.
2.
Press the
Sec/Single
button, the
C
LED should blink slowly.
3.
Press the Loft Duox Extra telephone the
F1
key, the
C
LED must remain off. This way you
have already confi gured the command attending to the relay. The
F1
remote relay activated
must have the same block address as the telephone.
By default, Continued is deactivated, so upon activating the
Set
terminal, the
F1
remote
relay is activated and and the Reset terminal deactivates the
F1
remote relay.
If you want to activate the Continued mode
1. Press the
PRG
button 3 times, the
T
led should light up.
2. Simultaneously press the
Min/All
and
Sec/Single
, all leds should remain off.
Notes:
- The time and mode (timer/Continued), confi gured in the relay transmitter does not effect
the receptor relay.
- Local mode (transmitter relay - relay on):
* SET ON -> Activates relay.
* RESET ON -> Deactivates relay.
- Continued mode:
Remote Relay Activation:
* SET ON -> Activates remote relay.
* SET OFF
RESET ON
If you want to activate the Continued mode.
1. Press the
PRG
button 3 times, the
T
led should light up.
2. Press the
Sec/Single
button, the
T
LED should blink once.
3. Press the PRG button, all the leds must remain off.
Note:
- In the push-button confi guration mode, if no button is pressed the relay returns to standby
and all leds turn off after 300 seconds.
Remote Relay deactivation.
2.5.1.5 ACTIVATE OR DEACTIVATE THE F2 RELAY FUNCTION
Function description.
* First operating mode:
You can activate or deactivate a second remote relay confi gured as F2 by activating the
Set terminal (button connected between the SET and - terminals), in the relay that we are
confi guring.
For this, the second relay must be confi gured as described in section:
2.5.2 RX Operating
Mode,
section:
2.5.2.6 ACTIVATING OR DEACTIVATING A RELAY UPON RECEIVING AN
ACTIVATE F2 RELAY COMMAND.
If the relay we are confi guring activates the Reset terminal (button connected between the
RESET and - terminals), the remote relay confi gured as F2 is deactivated.