Page 11
Function confi guration.
1. Make a call from a telephone in the installation and answer.
2.
Press the
PRG
button, the
C
led should light up.
3.
Press the
Min/All
button, the
C
LED should blink quickly.
4.
Press the
Lock-release
button on the previously used phone, the
C
led should turn off.
This way, the command is confi gured on the relay being serviced, now you must confi gure
the terminal to include the function on.
5.
Press the
PRG
button twice, the
D
led should light up.
6.
Press the
Sec/Single
button, the
D
LED should blink quickly.
7.
Make a call to the terminal you want to have the function. Upon making the call the
Relay
On
led turns on for about 1.5 seconds.
8.
Press the
PRG
button, all the leds must remain off. The function has been confi gured so
that when a call is made to the confi gured phone, you have 30 seconds to press the Lock-
release button (SET and -), and carry out the lock-release function over the panel you called.
Steps to change the terminal assigned the function.
1.
Press the
PRG
button twice, the
D
led should light up.
2.
Simultaneously press the
Min/All
and
Sec/Single
, the
D
led should remain off.
3. Repeats point 5 and 8 from the previous process.
Notes:
- This function only works with one terminal address. If you need to confi gure terminals
confi gured as “ALL,” it will not attend to any terminal address.
- In the push-button confi guration mode, if no button is pressed the relay returns to standby
and all leds turn off after 300 seconds.
2.5.1.2 LOCK-RELEASE FUNCTION IN CONFIGURED PANEL
Function description.
You can associate the duox relay to a panel so that the Set terminal (button connected be-
tween the SET terminals and -), send a lock-release command to the confi gured panel. This
function is useful for entrance door buttons far from the street-panel.
Function confi guration.
1. Make a call to a telephone in the installation from the panel you want to associate the
relay, and answer.
2.
Press the
PRG
button, the
C
led should light up.
3.
Press the
sec/single
button, the
C
LED should blink slowly.
4.
Press the
Lock-release
button on the previously used phone, the
C
led should turn off.
This way you have already confi gured the command attending to the relay.
Steps to change the panel assigned the function.
Carry out steps 1 to 4 of the previous process.
Note:
- In the push-button confi guration mode, if no button is pressed the relay returns to standby