Page 18
2.5.2 RX Operating Mode
- The mode where the relay activates the output and the confi gured command is received
and coincides with the other confi gured parameters.
-
To access this mode confi gure the bridge to
RX
mode.
FUNCTIONS:
-Activating relay upon receiving the
lock-release
command
- Activation the relay upon
receiving
a
call to residence command from a panel.
- Activation
of the relay
upon receiving a guard-unit call command.
- Activating
of the relay
upon receiving an auto-start command.
- Activation
of the relay
upon receiving an Activate F1 relay command.
- Activation
of the relay
upon receiving an Activate F2 relay command.
- Activation
of the relay
upon receiving an Activate/Deactivate command.
- Activation of the relay for an indefi nite time.
Note:
- Whenever terminals from different blocks are required to activate the same relay, it must be
confi gured as General Entrance.
2.5.2.1 ACTIVATION OF THE RELAY UPON RECEIVING A LOCK-RELEASE
COMMAND
Function description
You can confi gure the relay to activate upon receiving a
Lock-release
command from resi-
dence terminals.
The residence terminals send the lock-release command to the panel upon pressing the
lock-release button. The relay, if confi gured this way, can be activated upon receiving the
lock-release command. The residence terminals can send the lock-release command to a
specifi c panel or to all panels in the installation, understanding that this command is sent
individually to each of them.
- The lock-release command, relative to the
residence terminals
sending them can be
confi gured as:
* All installed terminals (ALL).
* Terminals from a list (maximum 100 terminals).
* Terminals included within a defi ned range (consecutive).
- The lock-release command, relative to the
panels
receiving them can be confi gured as:
* All panels (they individually receive each command, not all in the group).
For example: In the installation the panels are P1, P2, P3, P4 and P5. The residence
terminal can open the door of Panel P1 or Panel P2 or Panel P3 or Panel P4 or Panel
P5. Upon confi guring the lock-release command in All the panels, any time any panel
receives it the relay is activated.
* Only one panel.
For example: In the installation the panels are P1, P2, P3, P4 and P5. The residence
terminal can open the door of Panel P1 or Panel P2 or Panel P3 or Panel P4 or Panel
P5. Upon confi guring the lock-release command in a single panel, for example, Panel
P4, only when Panel P4 receives the command is the relay activated.