5. From a street panel, make a call to the
fi rst address in the range
. The last address should
be greater than the fi rst one. All leds should be off.
Note:
- To confi gure the fi rst and last addresses in the range to make the call from a push-button
panel, press the corresponding buttons for these addresses as indicated in steps 4 and
5. Remember that if the panel has a keypad, the call is made by entering the residence
the bell key.
Steps to DELETE the entered range.
1.
Press the
PRG
button twice, the
D
led should light up.
2.
Simultaneously press the
Sec/Single
and
Min/All
buttons. All leds should be off. The range
entered has been deleted.
Third step: Confi guration of the activation time.
To confi gure the activation time, follow point:
See:
2.4 CONFIGURING ACTIVATION TIME
VIA THE INTEGRATED BUTTONS (Sec/Single - Min/All)
2.5.2.3 ACTIVATING THE RELAY UPON RECEIVING A CALL TO GUARD UNIT
COMMAND
Function description.
You can confi gure the relay to activate upon receiving a
Call to guard unit
command from
residence terminals.
The residence terminals send the lock-release command to the panel upon pressing the lock-
release button (in stand-by). The relay, if confi gured this way, can activate upon receiving the
call guard unit command. The residence terminals can send the call guard unit command to
a specifi c guard unit or to all guard units in the installation, understanding that this command
is sent individually to each of them.
- The call to guard unit command, relative to the
residence terminals
sending them can be
confi gured as:
* All installed terminals (ALL).
* Terminals from a list (maximum 100 terminals).
* Terminals included within a defi ned range (consecutive).
- The call to guard unit command, relative to the
guard units
receiving them can be confi g-
ured as:
* All guard units (they individually receive each command, not all in the group).
For example: In the installation there are guard units C1, C2, C3, C4 and C5. The
residence terminal can call Guard unit C1 or Guard unit C2 or Guard unit C3 or Guard
unit C4 or Guard unit C5. Upon confi guring the call to guard unit command in All the
guard units, any time any guard unit receives it the relay is activated.
* Only one guard unit.
For example: In the installation there are guard units C1, C2, C3, C4 and C5. The
residence terminal can call Guard unit C1 or Guard unit C2 or Guard unit C3 or Guard
unit C4 or Guard unit C5. Upon confi guring the call guard unit command in a single
guard unit, for example, Guard unit C4, only when Guard unit C4 receives the call
guard unit command is the relay activated.