Page 57
c) Confi guration: Terminals included within a defi ned range (consecutive).
1. Via the arrows we select the
3. TERMINALS
menu and press
Ok.
2. Via the arrows we select
RANGE
and press
Ok.
3. Via the arrows we select the
3.1. RANGE START
menu and press
Ok.
4.
Via the numeric keypad, enter the
fi rst address in the range
and press
Ok.
5. Via the arrows we select the
3.1. RANGE END
menu and press
Ok.
6.
Via the numeric keypad, enter the
last address in the range
and press
Ok.
Note:
The last address should be greater than the fi rst one.
7. Upon turning the programmer off, the function is confi gured.
Third step: Confi guration of the activation time.
To confi gure the activation time, follow point:
3.2 CONFIGURING ACTIVATION TIMES
3.3.2.4 ACTIVATION OF THE RELAY UPON RECEIVING AUTO-START COMMAND
Function description.
You can confi gure the relay to activate upon receiving an
Auto-start
command from resi-
dence terminals.
In Duox installations the Auto-start is performed from the residence terminals with:
- Panel 0 of its own block, if audio terminals.
- Via a selection menu with Panel 0 or Panel 1 of the same block, or with Panel 0 of the
General Entrance, if for video terminals.
Note:
- The auto-start command is done on all panels (understanding that this command is sent
individually to each of them), there is no option for auto-start on a specifi c panel (within the
panels in which auto-start can be performed).
The residence terminals (whether audio or video) send the auto-start command to the panel.
The relay, if confi gured this way, can be activated upon receiving the auto-start command.
- The auto-start command, relative to the
residence terminals
sending them can be con-
fi gured as:
* All installed terminals (ALL).
* Terminals from a list (maximum 100 terminals).
* Terminals included within a defi ned range (consecutive).
- The lock-release command, relative to the
panels
receiving them can act on:
* All panels (they individually receive each command, not all in the group).