DESTINATION
receptor relay
ORIGIN
transmitter relay
(confi gured as Activa-
tion or Deactivation
upon RECEIVING
an Activate F1 relay
command.
second
REMOTE relay
(the one being con-
fi gured as SEND of
the Activation or De-
activation command
on the F1 relay)
fi rst relay
3.3.1.4 ACTIVATE OR DEACTIVATE THE F1 RELAY FUNCTION
Function description.
* First operating mode:
You can activate or deactivate a second remote relay confi gured as F1 by activating the
Set terminal (button connected between the SET and - terminals), in the relay that we are
confi guring.
For this, the second relay must be confi gured as described in section:
3.3.2 RX Operating
Mode,
section:
3.3.2.5 ACTIVATING RELAY UPON RECEIVING ACTIVATE F1 RELAY
COMMAND.
If the relay we are confi guring activates the Reset terminal (button connected between the
RESET and - terminals), the remote relay confi gured as F1 is deactivated.
* Second operating mode:
Continued Mode (TOGGLE). If a relay in charge of activating the second remote relay,
we activate Continued mode
(see:
3.2 CONFIGURATION OF ACTIVATION TIMES)
,
upon
activating the Set terminal on the fi rst relay, the second remote relay confi gured as F1 is
activated, and if the Set terminal is deactivated or the Reset terminal on the fi rst relay is
activated, the second remote F1 relay is deactivated.
Function confi guration.
1. Press the
On/Off
button, the display will show the
Duox Relay
and
version.
2. Via the arrows we select the
1. COMMAND
menu and press
Ok.
3. Via the arrows we select the
F1
command and press
Ok.
4. Via the arrows we select the
1.2. RELAY BLOCK
menu and press
Ok.
5. a) Via the number keypad enter the
address of the remote F1 relay’s block
we want
to activate.
b) If you press the arrows (up/down) we confi gure the
remote F1 relay
as
GENERAL
ENTRANCE
.
To end press
Ok.
6. Upon turning the programmer off, the function remains activated.
If you want to activate the Continued mode (TOGGLE).
1. Via the arrows we select the
1.3. TOGGLE MODE
menu and press
Ok.
2. Via the arrows we select
YES
or
NO
and press
OK
. If YES: the function is activated and
NO: the function is deactivated.
3. Upon turning the programmer off, the function is confi gured.