2.5.1.6 ACTIVATE OR DEACTIVATE THE REMOTE RELAY FUNCTION
Function description.
* First operating mode:
You can activate or deactivate a second remote relay by activating the Set terminal (button
connected between the SET and - terminals), in the relay that we are confi guring.
For this, the second relay must be confi gured as described in section:
2.5.2 RX Operating
Mode,
section:
2.5.2.7 ACTIVATING OR DEACTIVATION OF THE RELAY UPON RECEIV-
ING AN ACTIVATE/DEACTIVATE COMMAND.
If the relay we are confi guring activates the Reset terminal (button connected between the
RESET and - terminals), the remote relay is deactivated.
By default, Continued function is deactivated, so upon activating the
Set
terminal, the remote
relay is activated and the Reset terminal deactivates the remote relay.
Note: The time confi gured in the transmitter relay does not effect the receptor relay.
* Second operating mode:
Continued mode. If a relay in charge of activating the second remote relay, we activate
Continued mode
(see:
2.4 CONFIGURATION OF ACTIVATION TIMES VIA THE
INTEGRATED PUSH BUTTONS (Sec/Single - Min/All)
,
upon activating the Set terminal of
the fi rst relay, the second remote relay is activated, and if the Set terminal is deactivated
or the Reset terminal on the fi rst relay is activated, the second remote relay is deactivated.
If you want to deactivate the Continued mode.
1. Press the
PRG
button 3 times, the
T
led should light up.
2. Press the
Sec/Single
button, the
T
LED should blink once.
3. Press the PRG button, all the leds must remain off.
Note:
- In the push-button confi guration mode, if no button is pressed the relay returns to standby
and all leds turn off after 300 seconds.
TX
RX
3257
REF.
DISABLE
OUTPUT
12V 0.3A
SEC SINGLE
MIN ALL
OUT
NO
NC
C
RELAY
AV TRES CRUCES, 133
FERMAX ELECTRONICA, SAU
46017 VALENCIA - SPAIN
MADE IN SPAIN
BUS
OUTPUT
C
D
T
RX
PRG
MODULO RELE
DUOX
DUOX RELAY
MODULE
BUS INPUT
B
B
PRG
TX
B B
+12V
-
RESET/
SET
V
ON
3257
REF.
DISABLE
OUTPUT
12V 0.3A
SEC SINGLE
MIN ALL
OUT
NO
NC
C
RELAY
AV TRES CRUCES, 133
FERMAX ELECTRONICA, SAU
46017 VALENCIA - SPAIN
MADE IN SPAIN
BUS
OUTPUT
C
D
T
RX
PRG
MODULO RELE
DUOX
DUOX RELAY
MODULE
BUS INPUT
B
B
PRG
TX
B B
+12V
-
RESET/
SET
V
ON
DESTINATION
receptor relay
ORIGIN
transmitter relay
(confi gured as Activa-
tion or Deactivation
upon RECEIVING an
Activate or Deacti-
vate remote relay
command.
second
REMOTE relay
(the one being
confi gured as SEND
of the Activation or
Deactivation com-
mand on the remote
relay)
fi rst relay
Notes:
- This confi guration can not be made using integrated push buttons in the relay (Min/All -
Sec/Single), and must be done via the Duox Programmer, see the corresponding chapter
in Section
“3. CONFIGURATIONS - FUNCTIONS: PROGRAMMING WITH THE DUOX