Page 27
5. From a street panel, make a call to the
last address in the range
. The last address should
be greater than the fi rst one. All leds should be off.
Note:
- To confi gure the fi rst and last addresses in the range to make the call from a push-button
panel, press the corresponding buttons for these addresses as indicated in steps 4 and
5. Remember that if the panel has a keypad, the call is made by entering the residence
the bell key.
Steps to DELETE the entered range.
1.
Press the
PRG
button twice, the
D
led should light up.
2.
Simultaneously press the
Sec/Single
and
Min/All
buttons. All leds should be off. The range
entered has been deleted.
Third step: Confi guration of the activation time.
To confi gure the activation time, follow point:
See:
2.4 CONFIGURING ACTIVATION TIME
VIA THE INTEGRATED BUTTONS (Sec/Single - Min/All).
2.5.2.4 ACTIVATION OF THE RELAY UPON RECEIVING AUTO-START COMMAND
Function description.
You can confi gure the relay to activate upon receiving an
Auto-start
command from resi-
dence terminals.
In Duox installations the Auto-start is done from the residence terminals with:
- Panel 0 of its own block, if audio terminals.
- Via a selection menu with Panel 0 or Panel 1 of the same block, or with Panel 0 of the
General Entrance, if for video terminals.
Note:
- The auto-start command is done on all panels (understanding that this command is sent
individually to each of them), there is no option for auto-start on a specifi c panel (within the
panels in which auto-start can be performed).
The residence terminals (whether audio or video) send the auto-start command to the panel.
The relay, if confi gured this way, can be activated upon receiving the auto-start command.
- The auto-start command, relative to the
residence terminals
sending them can be con-
fi gured as:
* All installed terminals (ALL).
* Terminals from a list (maximum 100 terminals).
* Terminals included within a defi ned range (consecutive).
- The lock-release command, relative to the
panels
receiving them can act on:
* All panels (they individually receive each command, not all in the group).