Page 40
Steps to change the terminal assigned the function.
1. Via the arrows we select the
3.2. TERM LIST
menu and press
Ok.
2. Via the arrows we select
ERASE
and press
Ok.
3. With the arrows we go through the programmed terminals in the list and with the
Ok
we
can delete them. All terminals in the list must be deleted. Once all are deleted, press
ESC
.
4. Repeat steps 9 through 11 to program the new terminal (previous process).
3.3.1.2 LOCK-RELEASE FUNCTION IN A CONFIGURED PANEL
Function description.
You can associate the duox relay to a panel so that the Set terminal (button connected be-
tween the SET terminals and -), sends a lock-release command to the confi gured panel. This
function is useful for entrance door buttons far from the street-panel.
Function confi guration.
1. Press the
On/Off
button, the display will show the
Duox Relay
and
version.
2. Via the arrows we select the
1. COMMAND
menu and press
Ok.
3. Via the arrows we select the
DOOR OPENING
command and press
Ok.
4. Via the arrows we select the
2. PANELS
menu and press
Ok.
5. Via the arrows we select
ONE
and press
Ok.
6. With the arrows we select the type of
panel
we want to confi gure (Block Panel, Sub-block
Panel or general entrance panel) and press
Ok.
Note:
Depending on the type of panel selected, a different menu is displayed.
7. Via the number buttons we enter the
address
of the panel we want to confi gure and press
Ok.
8. Upon turning the programmer off, the function remains activated.
Steps to change the panel assigned the function.
Carry out steps 4 to 8 of the previous process.