Page 15
TX
RX
3257
REF.
DISABLE
OUTPUT
12V 0.3A
SEC SINGLE
MIN ALL
OUT
NO
NC
C
RELAY
AV TRES CRUCES, 133
FERMAX ELECTRONICA, SAU
46017 VALENCIA - SPAIN
MADE IN SPAIN
BUS
OUTPUT
C
D
T
RX
PRG
MODULO RELE
DUOX
DUOX RELAY
MODULE
BUS INPUT
B
B
PRG
TX
B B
+12V
-
RESET/
SET
V
ON
3257
REF.
DISABLE
OUTPUT
12V 0.3A
SEC SINGLE
MIN ALL
OUT
NO
NC
C
RELAY
AV TRES CRUCES, 133
FERMAX ELECTRONICA, SAU
46017 VALENCIA - SPAIN
MADE IN SPAIN
BUS
OUTPUT
C
D
T
RX
PRG
MODULO RELE
DUOX
DUOX RELAY
MODULE
BUS INPUT
B
B
PRG
TX
B B
+12V
-
RESET/
SET
V
ON
DESTINATION
receptor relay
ORIGIN
transmitter relay
(confi gured as Activa-
tion or Deactivation
upon RECEIVING
an Activate F2 relay
command.
second REMOTE
relay
(the one being
confi gured as SEND
of the command
for Activation or
Deactivation of the
F2 relay)
fi rst relay
Note:
- If you want to confi gure with the integrated buttons on the relay (Min/All - Sec/Single), you
need a telephone with an auxiliary F2 function (for example, an Extra phone, with an F2 button.
If you do not have a telephone with auxiliary F2 function (ex. an Extra telephone), you
must do so with the Duox Programmer, see the corresponding chapter in Section
“3.
CONFIGURATIONS - FUNCTIONS: PROGRAMMING WITH THE DUOX PROGRAMMER”.
Function confi guration.
1.
Press the
PRG
button, the
C
led should light up.
2.
Press the
Sec/Single
button, the
C
LED should blink slowly.
3.
Press on the Loft Duox Extra the
F2
button, the
C
led should turn off. This way you have
already confi gured the command attending to the relay. The
F2
remote relay activated
must have the same block address as the telephone.
By default, Continued is deactivated, so upon activating the
Set
terminal, the
F2
remote
relay is activated and and the Reset terminal deactivates the
F2
remote relay.
If you want to activate the Continued mode
1. Press the
PRG
button 3 times, the
T
led should light up.
2. Simultaneously press the
Min/All
and
Sec/Single
, all leds should remain off.
* Second operating mode:
Continued mode. If a relay in charge of activating the second remote relay, we activate
Continued mode
(see:
2.4 CONFIGURATION OF ACTIVATION TIMES VIA THE
INTEGRATED PUSH BUTTONS (Sec/Single - Min/All)
,
upon activating the fi rst relay´s Set
terminal, the second remote relay is confi gured as F2 is activated, and if the Set terminal
is deactivated or the Reset terminal on the fi rst relay is activated, the second F2 remote
relay is deactivated.
Notes:
- The time and mode (timer/Continued), confi gured in the relay transmitter does not effect
the receptor relay.
- Local mode (transmitter relay - relay on):
* SET ON -> Activates relay.
* RESET ON -> Deactivates relay.
- Continued mode:
Remote Relay Activation:
* SET ON -> Activates remote relay.
* SET OFF
RESET ON
Remote Relay deactivation: