Qubino 

               

The

 INNOVATIVE 

and 

SMALLEST

                                                 

                                                                                               

 

 

Flush 1 relay

                   

 

 
 

ORDERING CODE 

Z-WAVE FREQUENCY 

ZMNHAA2 

868,4 MHz 

ZMNHAA3 

921,4 MHz 

ZMNHAA4 

908,4 MHz 

ZMNHAA5 

869,0 MHz 

ZMNHAA6 

916,0 MHz 

 

This  Z-Wave  module  is  used  for  switching  on 
or  off  the  electrical  device  (e.g.  light,  fan,  etc 
...).  The  module  can  be  controlled  either 
through  Z-wave  network  or  through  the  wall 
switch.

 

The module is designed to be mounted inside 
a  “flush  mounting  box”,  hidden  behind  a 
traditional wall switch. 
Module  measures  power  consumption  of 
electrical  device  and  supports  connection  of 
digital temperature sensor. It is designed to act 
as  repeater  in  order  to  improve  range  and 
stability of Z-wave network. 

                                             

 

Supported switches 

 

Module  supports 

mono-stable

  switches 

(push  button)  and 

bi-stable

  switches.  The 

module is factory set to operate with bi-stable 
switches.   

 

Installation   

 

 

Before  the  installation  disconnect  power 
supply. 

 

Connect  the  module  according  to 
electrical diagram.   

 

Locate  the  antenna  far  from  metal 
elements (as far as possible).   

 

Do not shorten the antenna. 

 
Danger of electrocution!   

 

 

Module installation requires a great degree 
of  skill  and  may  be  performed  only  by  a 
qualified and licensed electrician. 

 

Even  when  the  module  is  turned  off, 
voltage  may  be  present  on  its  terminals. 
Any  works  on  configuration  changes 
related to connection mode or load must be 
always  performed  by  disconnected  power 
supply (disable the fuse). 

 

Note! 
 

Do not connect the module to loads exceeding 
recommended  values.  Connect  the  module 
only  in  accordance  to  the  below  diagrams. 
Improper connections may be dangerous. 

 

Package contents 

 

 

Flush 1 relay 

 

 

Electrical diagram 230VAC 

 

 

 

 
 

 

 
 

 

 

 
 
 

 

Notes for the diagram: 

 
 

 

 

Electrical diagram 24VDC 
 
   
 

 
 

 
 
 
 
 

 

 
Notes for the diagram: 

 
 
 

 

 
 

 

Durability  of  the  module  depends  on  applied 
load.  For  resistive  load  (light  bulbs,  etc.)  and 
10A  current  consumption  of  each  individual 
electrical  device,  the  durability  exceeds  100 
000  switches  of  each  individual  electrical 
device.   

 

Module  Inclusion  (Adding  to  Z-wave 
network) 

 

 

Connect module to power supply (with   
temperature  sensor  connected  -  if 
purchased), 

 

bring module within maximum 1 meter (3 
feet) of the main controller, 

 

enable  add/remove  mode  on  main 
controller 

 

auto-inclusion 

(30 

minutes 

after 

connected to power supply) or 

 

press  service  button 

S

  for  more  than  2 

second or 

 

press push button 

I1

 three times within 3s 

(3  times  change  switch  state  within  3 
seconds). 
 

Module  Exclusion/Reset  (Removing 
from Z-Wave network) 

 

 

Connect module to power supply   

 

bring module within maximum 1 meter (3 
feet) of the main controller, 

 

enable  add/remove  mode  on  main 
controller 

 

press  service  button 

S

  for  more  than  6 

second or 

 

press  push  button 

I1 

five  times  within  3s 

(5   
 

times  change  switch  state  within  3 
seconds) in the first 60 seconds after the 
module is connected to the power supply. 

By  this  function  all  parameters  of  the  module 
are set to default values and own ID is deleted 
If service button S is pressed more than 2 and 
less  than  6  second  module  is  excluded,  but 
configuration parameters are not set to default 
values.   
 

Association 

 

Association  enables  Flush  1  relay  module  to 
transfer  commands  inside  Z-Wave  network 
directly  (without  main  controller)  to  other 
Z-Wave modules. 
 

Associated Groups: 

Group  1:  basic  on/off  (triggered  at  change  of 
the output Q state and reflecting its state) up to 
16 nodes. 
Group  2:  basic  on/off  (triggered  at  change  of 
the input I2 state and reflecting its state) up to 
16 nodes. 
Group  3:  basic  on/off  (triggered  at  change  of 
the input I3 state and reflecting its state) up to 
16 nodes. 
Group 4: default reporting group (reserved for 
the main controller). 
 

Configuration parameters 

 

Parameter no. 1 – Input 1 switch type 

Available  configuration  parameters  (data  type 
is 1 Byte DEC): 

 

default value 1 

 

0 mono-stable switch type (push button) 

 

1 bi-stable switch type   

  Parameter no. 2 – Input 2 contact type 

Available  configuration  parameters  (data  type 
is 1 Byte DEC): 

 

default value 0 

 

0 NO (normally open) input type 

 

1 NC (normally close) input type 

Parameter no. 3 – Input 3 contact type 

Available  configuration  parameters  (data  type 
is 1 Byte DEC): 

 

default value 0 

 

0 NO (normally open) input type 

 

1 NC (normally close) input type 

 

Parameter  no.  10  -  Activate  /  deactivate 
functions ALL ON/ALL OFF

 

Available  configuration  parameters  (data  type 
is 1 Byte DEC): 

 

default value 255 

 

255 - ALL ON active, ALL OFF active 

 

0  -  ALL  ON  is  not  active  ALL  OFF  is  not 
active 

 

1 - ALL ON is not active ALL OFF active 

 

2 - ALL ON active ALL OFF is not active 

Flush  1  relay  module  responds  to  commands 
ALL  ON  /  ALL  OFF  that  may  be  sent  by  the 
main controller or by other controller belonging 
to the system.   

 
Parameter  no.  11  -  Automatic  turning  off 
relay after set time   

Available  configuration  parameters  (data  type 
is 2 Byte DEC): 

 

Default value 0 

 

0 - Auto OFF disabled   

 

1 – 65535 = 0,01second – 655,35 
seconds Auto OFF enabled with define 
time, step is 10mseconds. 

 

Parameter  no.  30  -  Saving  the  state  of  the 
relay after a power failure 

Available  configuration  parameters  (data  type 
is 1 Byte DEC): 

 

default value 0 

 

0  –  Flush  1relay  module  saves  its  state 
before power failure (it returns to the last 
position saved before a power failure) 

 

1 - Flush 1relay module does not save the   
state  after  a  power  failure,  it  returns  to 
"off" position. 

 
 
 

Neutral lead 

Live lead

 

Output for electrical device 

 

I3 

Input for switch /push button or sensor 

 

I2 

Input for switch /push button or sensor

 

I1 

Input for switch /push button 

 

TS 

Terminal  for  digital  temperature  sensor 
(only  for  Flush  1  relay  module 
compatible  digital  temperature  sensor, 
which must be ordered separately).

 

+ 24VDC

 

- 24VDC

 

Output for electrical device 

I3 

Input for switch /push button or sensor

 

I2 

Input for switch /push button or sensor

 

I1 

Input for switch /push button 

 

TS 

Terminal  for  digital  temperature  sensor 
(only  for  Flush  1  relay  module 
compatible  digital  temperature  sensor, 
which must be ordered separately).

 

Service button (used to 
add or remove module 
from the Z-Wave 
network). 

N

L

TS

I1 I2 I3 Q L N

+

-

TS

I1 I2 I3 Q L N

Summary of Contents for Flush 1

Page 1: ...nting box hidden behind a traditional wall switch Module measures power consumption of electrical device and supports connection of digital temperature sensor It is designed to act as repeater in order to improve range and stability of Z wave network Supported switches Module supports mono stable switches push button and bi stable switches The module is factory set to operate with bi stable switch...

Page 2: ...connect the module to loads exceeding recommended values Connect the module only in accordance to the below diagrams Improper connections may be dangerous Package contents Flush 1 relay Electrical diagram 230VAC Notes for the diagram N Neutral lead L Live lead Q Output for electrical device I3 Input for switch push button or sensor I2 Input for switch push button or sensor I1 Input for switch push...

Page 3: ...ule within maximum 1 meter 3 feet of the main controller enable add remove mode on main controller auto inclusion 30 minutes after connected to power supply or press service button S for more than 2 second or N 24VDC L 24VDC Q Output for electrical device I3 Input for switch push button or sensor I2 Input for switch push button or sensor I1 Input for switch push button TS Terminal for digital temp...

Page 4: ...an 2 and less than 6 second module is excluded but configuration parameters are not set to default values Association Association enables Flush 1 relay module to transfer commands inside Z Wave network directly without main controller to other Z Wave modules Associated Groups Group 1 basic on off triggered at change of the output Q state and reflecting its state up to 16 nodes Group 2 basic on off...

Page 5: ...active ALL OFF active 2 ALL ON active ALL OFF is not active Flush 1 relay module responds to commands ALL ON ALL OFF that may be sent by the main controller or by other controller belonging to the system Parameter no 11 Automatic turning off relay after set time Available configuration parameters data type is 2 Byte DEC Default value 0 0 Auto OFF disabled 1 65535 0 01second 655 35 seconds Auto OFF...

Page 6: ...centage comparing to previous actual power in Watts step is 1 NOTE if power changed is less than 1W the report is not send pushed independent of percentage set Parameter no 42 Power reporting in Watts by time interval Set value means time interval 0 65535 in seconds when power report is send Available configuration parameters data type is 2 Byte DEC default value 300 power report in Watts is send ...

Page 7: ...urement accuracy P 5 50W 3W P 50W 3 Digital temperature sensor range sensor must be ordered separately 50 125 C Operation temperature 10 40 C Distance up to 30 m indoors depending on building materials Dimensions W x H x D 41 8 x 36 8 x 15 4mm Weight 25g Electricity consumption 0 4W For installation in boxes Ø 60mm or 2M Switching Relay In case of load other than resistive pay attention to the val...

Page 8: ... COMMAND_CLASS_VERSION COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Endpoint 1 I2 Device Class GENERIC_TYPE_SENSOR_BINARY SPECIFIC_TYPE_NOT_USED Command Classes COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_BASIC Endpoint 2 I3 Device Class GENERIC_TYPE_SENSOR_BINARY SPECIFIC_TYPE_NOT_USED Command Classes COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_BASIC This product can be included and operated in any Z Wave ...

Page 9: ...ailable If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge This user manual is subject to change and improvement without n...

Reviews: