6.6. [0x69] RF Reset
The RF-field of the Reader antenna can be switched off for
t
rf
= <15 ms
by the command RF Re-
set. Thus, all Transponders which are within the antenna field of the Reader will be reset to their
base setting.
Host
→
Reader
1
2
3
4
5
6,7
0x02
07
COM-ADR
[0x69]
CRC16
Host
←
Reader
1
2
3
4
5
6
7,8
0x02
08
COM-ADR
[0x69]
STATUS
CRC16
Notes:
•
After a RF Reset the Reader is not able to receive a new Transponder before expiration of
t
rf
.
•
After a RF Reset, a Transponder which is located within the field has to be re-selected.
•