To change the READER-ID
you must write to the CFG0 immediately after the Login to the Reader
Notes:
•
A READER-ID = 0x00000000 disables the password function.
•
A read with the command
5.1. [0x80] Read Configuration
‘0x00000000’.
•
A changed password becomes valid after a Reader reset.
•
The command
5.3. [0x83] Set Default Configuration
ter if all configuration blocks are used.
•
The command
is used to enable configuration data
access.
Config Protection
By means of Config Protection, the access to the configuration parameters stored within the Read-
er
is protected by a 32-bit password, the "READER-ID". This means that only after a "Login" with a
valid READER-ID with the command
can configuration parameters in
the EEPROM of the Reader may be read and changed in the EEPROM of the Reader.