4.17. CFG37: Transponder Parameters UHF
The parameters of the CFG37 configuration block contain general UHF Transponder settings.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
IDDIB
0x00
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
IDDIB
(Identifier Data Interpretation Byte)
:
(Transponder.Miscellaneous.IdentifierInterpretationMode)
Defines in which way the Reader interprets and display the Identifier data read during in-
ventory process by using the inventory command or in Scan Mode.
0x00 – EPC
0x01 – do not use
0x02 – EPC and TID (UID)
Note:
If IDDIB is 0x02 then only the TID must be used to address commands (e.g. read,
write...) to the tag