5.3. [0x83] Set Default Configuration (Configuration Reset)
Using the command Set Default Configuration each configuration block can be reset to the manu-
facturer's setting.
Host
→
Reader
1
2
3
4
5
6
7...8
0x02
8
COM-ADR
[0x83]
CFG-ADR
CRC16
Host
←
Reader
1
2
3
4
5
6
7...8
0x02
8
COM-ADR
[0x83]
STATUS
CRC16
CFG-ADR:
Bit:
7
6
5
4
3
2
1
0
Function
LOC
MODE
CFGn: Address of Configuration Block
CFGn:
memory-address of the required configuration block
MODE:
specifies one or all configuration blocks
b0
configuration block specified by CFGn
b1
all configuration blocks
LOC:
specifies the location of the configuration block
b0
RAM
b1
RAM and EEPROM
Notes:
•
A set default configuration with reserved configuration blocks will cause an error code.