OBID
i-scan
®
Manual
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 89 of 125
H71101-2e-ID-B.doc
8.1.4. [0x23] Read Multiple Blocks
This command reads one or more data blocks. The supported Host commands depend on the dif-
ferent Transponder types.
REQUEST-DATA
6
7
1 Byte
UID_LNG
Bytes
1Byte
0x23
MODE
UID_LNG
UID
BANK
1 Byte
A_PW_LGT
Bytes
1 or 2 Bytes
( def. by
EXT_ADR)
1 Byte
A_PW_LGT
A_PW
DB-ADR
DB-N
RESPONSE-DATA (STATUS = 0x95)
7
ISO15693
ERROR
RESPONSE-DATA
7
8
9
10...n
DB-N
DB-SIZE
SEC-STATUS
DB
Repeated DB-N times
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
EXT_ADR
UID_LF
SEC
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
SEC:
b0
SEC-STATUS always = 0x00
b1
security status of followed data block in SEC-STATUS
UID_LF:
If this bit is set the parameter UID_LNG must inserted into the protocol.
b0:
The protocol UID_LNG doesn't include the UID_LNG byte and
the UID field has a fixed length of 8 byte, from byte 6 to byte 13.
b1:
The protocol includes the parameter UID_LNG. The UID has a variable
length as defined in UID_LNG.
Summary of Contents for OBID i-scan ID ISC PRHD102
Page 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Page 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Page 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Page 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...