OBID
i-scan
®
Manual
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 39 of 125
H71101-2e-ID-B.doc
4.9. CFG12: Scan Mode - Filter
Byte
0
1
2
3
4
5
6
0x00
VALID-TIME
1
0x00
0x00
0x00
0x00
0x00
Default
0x0037
5,5sec.
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
VALID-TIME:
(0...65535 x 100 ms = 0 ms ... 6553,5 sec)
(OperatingMode.ScanMode.Filter.TransponderValidTime)
The VALID-TIME defines the period in which the Reader does not transmit the Trans-
ponder data a second time, after it has transmitted it the first time. (regardless whether the
Transponder is in the detection range of the reader during VALID-TIME or not). The
VALID-TIME starts after the data transmission from the Transponder to the Reader..
Transponder in field
VALID-TIME
Data output
t
r
:
Time to read the Transponder data
t
o
:
Data Transmission from the Reader to the host
t
s
:
VALID-TIME
As long as the VALID-TIME is active, the Transponder can be in the detection
range of the reader or outside of it.
Note:
•
Changing of VALID-TIME only becomes effective after writing / saving configura-
tion block CFG12 to EEPROM.
start of read
t
r
t
r
t
o
t
s
t
o
t
s
Summary of Contents for OBID i-scan ID ISC PRHD102
Page 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Page 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Page 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Page 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...