4.7. CFG10: Trigger
The configuration blocks contains parameters for the trigger configuration.
Byte
0
1
2
3
4
5
6
Contents
TRIGGER-
MODE
0x00
0x00
0x00
0x00
0x00
0x00
Default
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
TRIGGER-MODE (OperatingMode.ScanMode.Trigger.Mode)
defines the mode of the scanner.
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
mode
0
mode:
b00:
Single Read:
(active for read duration – stops after good read)
When all Transponders in detection range has been decoded, the
Reader will stop the scan. The Reader must be triggered again to read
other Transponders.
b01:
Continuous Read:
The Reader will read as much Transponders as it can decode regard-
less whether it is the same or not. This mode is mainly used for demon-
stration and diagnostic.