OBID
i-scan
®
Manual
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 24 of 125
H71101-2e-ID-B.doc
BAUD
1
: (HostInterface.Serial.Baudrate)
By means of this byte the baud rate of the asynchronous interface can be defined.
0x05:
4800 baud
0x06:
9600 baud
0x07:
19200 baud
0x08:
38400 baud
0x09:
57600 baud
0x0A:
115200 baud
0x0B:
230400 baud
Note:
•
Changing of BAUD only becomes effective after writing / saving configuration
block CFG1 to EEPROM and a reset of the Reader.
•
The Reader sets the baud rate to 38400 baud, if the user sets an invalid baudrate.
•
Not available by the USB-Reader
TRANS-FORM
: (HostInterface.Serial…)
By means of this byte, several parameters for the data transmission format of the asyn-
chronous interface can be defined.
Bit:
7
6
5
4
3
2
1
0
Function:
0
0
0
0
S
D
P
P: (HostInterface.Serial.Parity)
Kind of Parity
b00:
non Parity
b01:
even Parity
b10:
odd Parity
b11:
- do not use -
D: (HostInterface.Serial.Databits)
Number of Data Bits
b0:
8 Data Bits
b1:
- do not use -
S: (HostInterface.Serial.Stopbits)
Number of Stop Bits
b0:
1 Stop Bit
b1:
- do not use –
2
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = 0x11.
Summary of Contents for OBID i-scan ID ISC PRHD102
Page 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Page 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Page 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Page 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...