OUT-S:
OUT-S (Output State) defines the status of the output during the time defined in OUT-
TIME and provides the possibility to allocate its own flashing-frequency to each output.
Bit:
7
6
5
4
3
2
1
0
Function:
0
0
0
0
OUTx-frq
OUTx-mode
OUTx-mode:
b00
UNCHANGED
OUT-TIME has no effect on the status of the output
b01
ON
output for OUT-TIME = active
b10
OFF
output for OUT-TIME = inactive
b11
FLASH
output for OUT-TIME = with OSF alternating
OUTx-frq:
b11
1 Hz
b10
2 Hz
b01
4 Hz
b00
8 Hz
OUT-TIME:
By the values defined by “OUT-TIME”, the outputs can be activated temporary limited or
unlimited.
An exception are the time values 0 and 65535 (0xFFFF) (see following table).
0x0001
1 x 100ms
-> 100ms
...
...
0xFFFE
65534 x 100ms -> 1:49:13 h
0xFFFF
continuously active
Notes:
•
In order to reset a continuously active time, OUT-TIME = 1 has to be sent to
the Reader, which effects a change to the idle status after 100 ms.
•
The continuous activation is being set back after a reset or a power failure.
Summary of Contents for OBID i-scan ID ISC PRHD102
Page 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Page 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Page 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Page 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...