OBID
i-scan
®
Manual
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 35 of 125
H71101-2e-ID-B.doc
4.8. CFG11: Scan Mode – Read Data
The parameters of the CFG11 configuration block contain Scan Mode settings. To enable Scan
Mode the SCAN-E bit in the READER-MODE register of the configuration block 4.2. CFG1:
Byte
0
1
2
3
4
5
6
Contents TR-DATA-1
TR-DATA-2
TR-DATA-3
Bank
DB-ADR
0x00
Default
0x71
0x00
0x00
0x01
0x0000
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
D-START
D-LGT
Default
0x00
0x0004
TR-DATA
1 2
: (OperatingMode.ScanMode.Data…..)
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
Exten-
sion
-
-
-
Byte
Order
DB
-
DB
SNR
SNR
(OperatingMode.ScanMode.DataSelector.Uid)
b0:
no Serial Number will be stored
b1:
Serial Number will be stored
DB
(OperatingMode.ScanMode.DataSelector.Data)
b0:
no data block will be stored
b1:
data block will be stored
Byte Order DB (OperatingMode.ScanMode.DataSource.ByteOrder)
b0:
MSB first
b1:
LSB first
Extension
If this flag is set TR-DATA-2 is present
Notes:
•
If the bits UID and DB are set to 0, the scan-mode is switched off
4
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = [0x11].
Summary of Contents for OBID i-scan ID ISC PRHD102
Page 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Page 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Page 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Page 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...