OBID
i-scan
®
Manual
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 87 of 125
H71101-2e-ID-B.doc
8.1.2. [0x02] Stay Quiet
This command sets one Transponder to Quiet State.
REQUEST-DATA
6
7
8-15
0x02
MODE
UID
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b001
addressed
UID:
Read only UID of the Transponder.
Note:
•
This command is only available for ISO15693 Transponders.
Summary of Contents for OBID i-scan ID ISC PRHD102
Page 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Page 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Page 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Page 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...