OBID
i-scan
®
Manual
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 96 of 125
H71101-2e-ID-B.doc
8.1.7. [0x26] Reset to Ready
This command sets one ISO 15693 Transponder to Ready State.
REQUEST-DATA
6
7
(8...15)
0x26
MODE
UID
RESPONSE-DATA (STATUS = 0x95)
7
ISO15693
ERROR
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS
= 0x95.
Note:
•
This command is only available for ISO15693 Transponders.