background image

Advanced

 

Handheld

 

High

Speed

 

Laser

 

Scanner

 

1

                     
                           ZEBEX

Z-3190BT ; Z-3191BT ; Z-3192BT  BT wireless barcode scanner

CR-90  BT wireless communication cradle

Summary of Contents for z3190BT

Page 1: ...Advanced Handheld High Speed Laser Scanner 1 ZEBEX Z 3190BT Z 3191BT Z 3192BT BT wireless barcode scanner CR 90 BT wireless communication cradle...

Page 2: ......

Page 3: ...ipment does cause harmful interference to radio or television reception which can bedetermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or m...

Page 4: ...ical biological manual or otherwise except for brief passages which may be quoted for purposes of scholastic or literary review without express written consent and authorization We reserve the right t...

Page 5: ...necessary the user may consult the manufacturer and authorized dealer or experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Fede...

Page 6: ...hazard Optical instruments include binoculars magnifying glasses and microscopes but do not include normal eye glasses worn by the user CAUTION Use of controls or adjustments or performance of proced...

Page 7: ...on the Scanner 7 How to Scan 8 Radio Communication Host Type 9 Cradle Host Mode 9 SPP Mater SPP Slave Mode 9 HID Mode 9 Paging the Scanner 10 Scanner USB online to Host 10 USB Online Mode 10 Visible I...

Page 8: ......

Page 9: ...ly transferred to the connected host in a 100 meter connection range in open space or 75 meter range in indoor environments the actual communication range may vary due to different indoor placement Th...

Page 10: ...S MANUAL Metal Charging Contacts Product Overview Scanner Cradle Function Trigger LED indicator Charging Contacts Host Connector DC Power Connector LED Indicator Buzzer Trigger Cable Connector Exit W...

Page 11: ...anner with battery Scanner cradle optional with stand without stand Li ion battery pack Communication cable for cradle optional Mini USB B to mini USB A cable 5V USB Power adapter CD ROM or handbook C...

Page 12: ...install the batteries Always use the rechargeable batteries provided by the manufacturer to avoid any non compatible danger or void the warranty Unscrew the cap from the battery compartment at the bot...

Page 13: ...nsert the RJ 45 connector on the bottom of the cradle You will hear a clear and short click sound then connect the other end to the host 2 Connect the included USB cable of mini USB port in the bottom...

Page 14: ...cating scanner is in contact with the cradle 3 The battery begins charging when the scanner LED indicator starts flashing green LED turns steady green when charging is complete Approx charging time 4...

Page 15: ...on charging will auto power on scanner Batteries are shipped may not ne full charged and should be fully charged for maximum charge capacity Recommended charging environment is temperature in 0 C 35 C...

Page 16: ...wer on the scanner 2 Press the trigger and aim at the barcode as illustrated 3 When decoding is successful the scanner beeps and the LED indicates blue Presentation Scanning 1 Put the scanner into the...

Page 17: ...e delivery box are paired in factory As soon as both are powered on they should find and connect to each other immediately However under special circumstance that the scanner and the cradle are not pa...

Page 18: ...he scanner make 3 beep sounds and blue LED flash 3 times if it is in range Scanner USB online to Host The scanner provides other ways for you to connect to the host When the radio communication is not...

Page 19: ...or radio connection flash time 0 5s 0 5s Blue fast Flashing Radio connecting Blue Slow Flashing Device connected flash time 0 03s 3s 1 Blue Flashing A barcode was decoded successfully Blue Fast Flashi...

Page 20: ...ted Sound Indicators When the scanner is in operation it provides audible feedback The beeps indicate the status of the scanner Beep Indication A long beep Power on scanner One beep A barcode has been...

Page 21: ...in the data protocol or packing could confirm the data reliability Refer to below for different setting options a No ACK NAK protocol b ACK NAK only c Frame packing BT Scanner Remote BT device BT sca...

Page 22: ...sulated data length excluding header character Format Byte FEH Differentiate data format barcode data is always FEH Data ID The number of each data If receive the same ID more than once only the first...

Page 23: ...ld Gun Type Scanner 15 USER S MANUAL Barcode Type Table Code Value Code39 0x11 Codabar 0x01 Code128 0x03 Interleaved 2 5 0x02 Code93 0x06 UPC E 0x14 UPC A 0x24 EAN 8 0x34 EAN 13 0x44 Chinese Post Code...

Page 24: ...barcode and save the new configuration 5 To give up a configuration change power off the scanner before scanning the End of Configuration barcode or scan the Abort barcode 6 For some parameter setting...

Page 25: ...efault Radio communication Bluetooth host Cradle Host Pairing mode Unlocked Data transmit Normal Radio protocol timeout 5 seconds Power off timeout 20 minutes Encryption Enable Cradle Host RS 232 comm...

Page 26: ...cy Medium Duration Medium Operating Parameter Default Scan mode Trigger mode Stand mode Enable Header and trailer None Inter message delay None Inter character delay None Code Identifiers Default Iden...

Page 27: ...nded identifier code RX Default Data Transmit Format Code Message format EAN 13 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 EAN 8 D1 D2 D3 D4 D5 D6 D7 D8 UPCA D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 UPC...

Page 28: ...echarge and transmit data You may enable or disable the functions using the following settings Disable USB communication USB online scan disable Disable USB communication Enable USB communication USB...

Page 29: ...o another scanner so you must unpair the scanner before continuing 2 Power on the scanner and enable cradle host mode if necessary Cradle Host mode enable Enable cradle mode with this set 3 Use the sc...

Page 30: ...pairing instructions To connect a Bluetooth device to Window based system for the first time 1 Turn on the host computer and activate its Bluetooth connection 2 Select Add Bluetooth device Or open th...

Page 31: ...able SPP Master mode 3 Scan Set Bluetooth address to set the address Set Bluetooth address SPP Master only Set Bluetooth address for SPP Master connection 4 Use the ASCII table in Programming Guide to...

Page 32: ...th devices in its surrounding 3 The scanner should be on the list of discoverable devices The default name of the scanner is ZBBT Select ZBBT and input the pin code to connect scanner to the phone The...

Page 33: ...evice name set label Default name is ZBBT 2 Use the ASCII table in Programming Guide to input the name Max 12 digits 3 Scan Confirm Setting to store the new name Friendly device name set Change the di...

Page 34: ...ers may modify this setting according to their preferences Normal When the scanner is within the connection range the scanned data will be transferred to the host computer immediately If the scanner i...

Page 35: ...the bar code 2 Batch mode Note Scanner LED indicator will not flash while waiting for connection in this mode Clearing Batch Use the settings in this section to clear the stored data Clear batch data...

Page 36: ...cradle Data is ready to be transferred upon placement on the cradle Press and hold the trigger for over 1 second to send the data Cradle radio connected is required Batch Mode Sounds Settings Use the...

Page 37: ...n cradle host to factory defaults Return to USB default Communication cradle link required Return to wand emulation default Communication cradle link required Return to RS232 default Communication cra...

Page 38: ...scan mode The scanner is still active after the data is transmitted but the successive transmission of the same barcode is not allowed when the trigger switch is pressed again Alternate mode The scann...

Page 39: ...is mode the scanner can not pair with another cradle Undo pairing Undo the pairing between the cradle and the scanner Scanner On Cradle sound alert enable Enable beep sound alert when scanner is place...

Page 40: ...can Ignore radio communication BT HID mode BT HID mode Combo keyboard For Apple mode Must execute BT HID mode first SPP Master Slave mode Scanner SPP Master enable SPP Master Connect Bluetooth address...

Page 41: ...e pin code Confirm Setting for address device name and pin code setting required Required Pair with slave SPP Master Discover enable Discover disable Encryption enable Encryption disable Data communic...

Page 42: ...atch Data By Scanning Label Clear batch data after send Clear batch data by scanning Delete batch data label Delete batch data Send Batch Data on line USB cable contact Send Batch data on cradle Out o...

Page 43: ...ion Radio protocol communication parameter Radio protocol timeout 3 sec Radio protocol timeout 5 sec Radio protocol timeout 8 sec Radio protocol timeout 10 sec Radio protocol timeout 13 sec Radio prot...

Page 44: ...ation Power off timeout parameter Power off timeout 5 min Power off timeout 10 min Power off timeout 20 min Power off timeout 30 min Power off timeout 1 hr Power Off timeout 2 hr Power Off timeout 4 h...

Page 45: ...R S MANUAL Start Of Configuration Power Always On Power off by scanning this label Link beeper enable Link beeper disable Power up beeper enable Power up beeper disable Same Code Delay 50 msec 100 mse...

Page 46: ...Wireless Handheld Gun Type Scanner 38 USER S MANUAL Start Of Configuration 400 msec 500 msec 600 msec 700 msec 800 msec 1000 msec Infinite End Of Configuration...

Page 47: ...Configuration Operation Function Setting Good Read Beeper Tone Selection Medium beeper tone High beeper tone Low beeper tone Speaker disable Good Read Beeper Tone Selection Medium beeper tone High bee...

Page 48: ...Wireless Handheld Gun Type Scanner 40 USER S MANUAL Start Of Configuration Beeper duration Selection Long Medium Short Ultra Short Ultra Long End Of Configuration...

Page 49: ...tor disable Good read beeper and vibrator enable Vibration duration 100msec Vibration duration 200msec Vibration duration 300msec Vibration duration 400msec Vibration duration 500msec Vibration durati...

Page 50: ...Wireless Handheld Gun Type Scanner 42 USER S MANUAL Start Of Configuration Inter Character Delay 0 ms 2 ms 5 ms 10 ms 20 ms 50 ms Inter Message Delay 0 ms 100 ms 500 ms 1000 ms End Of Configuration...

Page 51: ...f Configuration Interface Settings 1 RS 232C Interface Setting Baud Rate 115200 19200 9600 4800 2400 1200 Parity Bit Even parity Odd parity Mark parity Space parity None parity Stop Bit 1 stop bit 2 s...

Page 52: ...ing ACK NAK Xon Xoff RTS CTS Enable BEEPER ON BEL CHARACTER Ignore Beep on BEL character ACK NAK response time 300ms ACK NAK response time 2 sec ACK NAK response time 500 ms ACK NAK response time 3 se...

Page 53: ...iguration Message Terminator RS 232 message terminator none RS 232 message terminator CR LF RS 232 message terminator C RS 232 message terminator LF RS 232 message terminator H tab RS 232 message term...

Page 54: ...language support GERMANY Keyboard language support FRENCH send scan code Keyboard language support SPANISH send scan code Keyboard language support ITALIAN send scan code Keyboard language support Sw...

Page 55: ...Wireless Handheld Gun Type Scanner 47 USER S MANUAL Start Of Configuration Message Terminator Keyboard terminator none Keyboard terminator Enter Keyboard terminator H TAB End Of Configuration...

Page 56: ...ard mode ALT method Keyboard language support USA Keyboard language support GERMANY Keyboard language support FRENCH send scan code Keyboard language support SPANISH send scan code Keyboard language s...

Page 57: ...that symbology Enable Wand output data format as CODE39 Wand emulation data output black high Scan this bar code to set quiet zones and spaces low and bars high Wand emulation data output black low Sc...

Page 58: ...ms narrow element width Wand emulation speed medium This option allows the transmission of wand emulation at 600us narrow element width Wand emulation speed high This option allows the transmission of...

Page 59: ...5 Codabar start stop character transmission none CB06 Codabar start stop character transmission A B C D CB07 Codabar start stop character transmission DC1 DC4 CB08 Codabar start stop character transmi...

Page 60: ...ode Label Description CB13 No check character CB14 Validate modulo 16 but don t transmit CB15 Validate modulo 16 and transmit DC50 Codabar data redundant check off DC51 Codabar data redundant check 1...

Page 61: ...de 39 disable RC13 Code 32 enable RD13 Code 32 disable DC00 Code 39 data redundant check off DC01 Code 39 data redundant check 1 DC02 Code 39 data redundant check 2 DC03 Code 39 data redundant check 3...

Page 62: ...Code 39 check digit calculate but without transmit 3907 No check character 3908 Code 39 maximum length setting 3909 Code 39 minimum length setting SET Confirm to save this setting required for reading...

Page 63: ...a redundant check 1 DC32 Code 93 data redundant check 2 DC33 Code 93 data redundant check 3 9301 Code 93 maximum length setting 9302 Code 93 minimum length setting SET Confirm to save this setting req...

Page 64: ...able DC40 Code 128 data redundant check off DC41 Code 128 data redundant check 1 DC42 Code 128 data redundant check 2 DC43 Code 128 data redundant check 3 1803 No check character 1804 Calculate but no...

Page 65: ...code disable DC60 Chinese post code data redundant check off DC61 Chinese post code data redundant check 1 DC62 Chinese post code data redundant check 2 DC63 Chinese post code data redundant check 3 S...

Page 66: ...ing MS02 MSI Plessy minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting MS03 MSI Plessy double check digit calculate but not transmit MS04...

Page 67: ...1102 Code 11 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting 1103 Code 11 one check digit verification 1104 Code 11 two check digit ve...

Page 68: ...RD04 ITF 2 of 5 disable RC09 IATA code enable RD09 IATA disable DC80 ITF 25 data redundant check off DC81 ITF25 data redundant check 1 DC82 ITF25 data redundant check 2 DC83 ITF25 data redundant check...

Page 69: ...IT01 ITF 2 of 5 code maximum length setting IT02 ITF 2 of 5 code minimum length setting IT06 ITF 2 of 5 one fixed length setting IT07 ITF 2 of 5 two fixed length setting SET Confirm to save this sett...

Page 70: ...f 5 code disable D051 Standard 2 of 5 code maximum length setting D052 Standard 2 of 5 code minimum length setting SET Confirm to save this setting required for reading full ASCII table and length set...

Page 71: ...code disable D251 Industrial 2 of 5 code maximum length setting D252 Industrial 2 of 5 code minimum length setting SET Confirm to save this setting required for reading full ASCII table and length se...

Page 72: ...AN convert to ISSN ISBN enable RD11 EAN convert to ISSN ISBN disable RC03 UPC EAN JAN enable RD03 UPC EAN JAN disable UE01 UPC EAN JAN all enable UE02 EAN 8 or EAN 13 enable UE03 UPC A and EAN 13 enab...

Page 73: ...disable UE15 Force UPC A to EAN 13 format enable UE16 Force UPC A to EAN 13 format disable UE44 Force EAN 8 to EAN 13 format enable UE45 Force EAN 8 to EAN 13 format disable UE17 Transmit UPC A check...

Page 74: ...it disable UE27 Transmit UPC A leading character enable UE28 Transmit UPC A leading character disable UE30 Add on format with separator UE31 Add on format without separator UE60 EAN 13 country code fi...

Page 75: ...t check 1 DC16 UPC E data redundant check 2 DC17 UPC E data redundant check 3 DC20 EAN 13 data redundant check off DC21 EAN 13 data redundant check 1 DC22 EAN 13 data redundant check 2 DC23 EAN 13 dat...

Page 76: ...t sent for other UE37 EAN UPC addon mandatory for 378 379 French Supplement requirement optional for other UE36 EAN UPC addon mandatory for 434 439 German Supplement requirement not sent for other UE3...

Page 77: ...ner 69 USER S MANUAL Start Of Configuration 12 Telepen Parameter Setting Barcode Value Barcode Label Description RC25 Telepen enable RD25 Telepen disable TE03 Telepen numeric mode enable TE04 AIM Tele...

Page 78: ...12 Matrix 2 of 5 disable D151 Matrix 2 of 5 maximum length setting D152 Matrix 2 of 5 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting D...

Page 79: ...Formally RSS Limited GS1 DataBar Limited Group 3 GS1 DataBar Expanded Formally RSS Expanded GS1 DataBar Expanded GS1 DataBar Expanded Stacked GS1 DataBar Omnidirectional Formally RSS 14 Barcode Value...

Page 80: ...Value Barcode Label Description RC16 GS1 DataBar Limited enable RD16 GS1 DataBar Limited disable SS10 Transmit GS1 DataBar Limited check digit SS11 Don t transmit GS1 DataBar Limited check digit SS12...

Page 81: ...panded enable RD17 GS1 DataBar Expanded disable SS07 GS1 DataBar Expanded EAN 128 emulation enable SS06 GS1 DataBar Expanded EAN 128 emulation disable SS08 GS1 DataBar Expanded check digital enable SS...

Page 82: ...d IS03 Enable identifier code table as AIM standard CI01 Code 39 identifier code setting CI02 ITF 2 of 5 identifier code setting CI03 Chinese Post Code identifier code setting CI04 UPC E identifier co...

Page 83: ...de setting CI12 GS1 DataBar Omnidirectional identifier code setting CI13 GS1 DataBar Limited identifier code setting CI14 GS1 DataBar expanded identifier code setting CI15 Industrial 2 of 5 identifier...

Page 84: ...Description CP11 Add code length as header enable 2 digits CP12 Add code length as header disable 2 digits HT01 Header Preamble HT02 Trailer Postamble HT03 Truncate header character HT04 Truncate trai...

Page 85: ...uration Barcode Type Setting Barcode Value Barcode Label Description Q Code39 A Codabar B ITF2 of 5 C Code128 F Code 93 G MSI E Chinese Post Code 4 EAN 8 D EAN 13 D UPC A T UPC E U GS1 DataBar Standar...

Page 86: ...Full ASCII DC4 Function key F4 14 Full ASCII ACK Function key Down arrow 06 Full ASCII NAK Function key F5 15 Full ASCII BEL Function key Left arrow 07 Full ASCII SYN Function key F6 16 Full ASCII BS...

Page 87: ...y ALT L 1F Full ASCII 2E Full ASCII SP 20 Full ASCII 2F Full ASCII 21 Full ASCII 0 30 Full ASCII 22 Full ASCII 1 31 Full ASCII 23 Full ASCII 2 32 Full ASCII 24 Full ASCII 3 33 Full ASCII 25 Full ASCII...

Page 88: ...SCII 3E Full ASCII M 4D Full ASCII 3F Full ASCII N 4E Full ASCII 40 Full ASCII O 4F Full ASCII A 41 Full ASCII P 50 Full ASCII B 42 Full ASCII Q 51 Full ASCII C 43 Full ASCII R 52 Full ASCII D 44 Full...

Page 89: ...ASCII 5C Full ASCII k 6B Full ASCII 5D Full ASCII l 6C Full ASCII 5E Full ASCII m 6D Full ASCII _ 5F Full ASCII n 6E Full ASCII 60 Full ASCII o 6F Full ASCII a 61 Full ASCII p 70 Full ASCII b 62 Full...

Page 90: ...L Start Of Configuration Full ASCII Code 39 Table continued Code 39 ASCII Hexa code Code 39 ASCII Hexa code Full ASCII x 78 Full ASCII 7C Full ASCII y 79 Full ASCII 7D Full ASCII z 7A Full ASCII 7E Fu...

Page 91: ...enable USB virtual COM port 1 Connect the handheld scanner and the host e g a PC with a USB interface cable 2 Enable USB virtual COM port with programming barcode on page 29 3 After the programming th...

Page 92: ...t Example If the barcode length is 4 to 12 digits the steps would be as below Start of Configuration Set up minimum barcode length Set up maximum barcode length End of Configuration Use the ASCII tabl...