5. Protocols for Reader Configuration
The Reader configuration protocols allow the Reader to be adapted to the conditions found in indi-
vidual applications. For details about the Protocol Frame see:
Access to the configuration parameters is gained only after a 6.10. [0xA0] Reader-Login command
with the correct READER-ID.
In order to avoid unauthorized data access, the Reader is equipped with the following protection
mechanism:
Config-Protection:
Access locking for the configuration parameters stored in the EEPROM of the Reader.
5.1. [0x80] Read Configuration
By using the Read Configuration the actual configuration of the Reader can be detected. In order
to do this, the configuration is read in blocks of 14 bytes each and addressed by CFGn in the byte
CFG-ADR.
Host
→
Reader
1
2
3
4
5
6
7-8
0x02
8
COM-ADR
[0x82]
CFG-ADR
CRC16
Host
←
Reader
1
2
3
4
5
6
7 .. 20
21-22
0x02
22
COM-ADR
[0x82]
STATUS
CFG-REC
CRC16
CFG-ADR
Bit:
7
6
5
4
3
2
1
0
Function
LOC
0
CFGn: Address of Configuration Block
CFGn:
memory-address of the required configuration block
LOC:
specifies the location of the configuration block
b0
RAM
b1
EEPROM
CFG-REC:
14 bytes configuration block read from address CFGn in CFG-ADR.
Note:
A read configuration from EEPROM with reserved configuration blocks will cause an 0x15
Read Protect error code.
6
see ANNEX D: Index of Status Bytes
7
see Chapter 4. Configuration Parameters (CFG)
Summary of Contents for OBID i-scan ID ISC PRHD102
Page 77: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 77 of 125 H71101 2e ID B doc...
Page 78: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 78 of 125 H71101 2e ID B doc...
Page 79: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 79 of 125 H71101 2e ID B doc...
Page 80: ...OBID i scan Manual ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 80 of 125 H71101 2e ID B doc...