background image

 

 

 

User’s Manual 

Wireless Barcode Scanner

 

 

 

 

 

 

 

 

 

Summary of Contents for D90E series

Page 1: ...User s Manual Wireless Barcode Scanner ...

Page 2: ...hirteen Performance Parameter Page 13 Part Fourteen Problems Solutions Page 14 Part Fifteen Technical Support After Sale Service Page 17 Appendix Barcode Setting 1 General Setting Page 17 2 Switch For Recognition Type Page 18 3 Length Configuration Page 21 4 Check Code Output Switch Setting Page 23 5 Error Check Switch Settings Page 25 6 Leading Code Output Setting Page 26 7 Complement Code Output...

Page 3: ... sure with high speed to read all ID barcode Now it is widely using in supermarket storage and logistics book store bank transportation post industry factory production line and so on Main features Excellent scanning performance Fashion design light flexible convenient Own proprietary intellectual property rights Using special communication technology to support one to many networking and many for...

Page 4: ...ion memory function disable or Factory Reset to clear the recorded barcode that is to say make scanner with memory space then can go on reading barcode 4 Low Power Consumption During setting duration if scanner does not work scanner will be turned off automatically If need to work again just press the scanner button it can return to working condition If scanner does not finish uploading barcode da...

Page 5: ... well with relative receiver unless user want to do advance network setting usually user is no need to match again Please follow up the following steps to install 1 Outer antenna connect to receiver tighten the screw 2 USB line connect to receiver then the other side of USB line connect with PC after connecting well the indicator light of antenna can be flashing 3 Create a new text on PC such as T...

Page 6: ...e scanner and receiver are inside effective transmission distance Part Six Memory When scanner is far away from the receiver or environment interferes data transmission will fail at this moment scanner can record the reading barcode data After communication signal return to normal according to first in first out principle scanner can send out the recorded barcode data automatically If fail to send...

Page 7: ...ner is closed or low battery indicator light can be flashing Re charging time is about 2 hours and a half power indicator light will be flashing during re charging this light is on all the time Part Ten Matching Networking When out of factory scanner has matched well with relative receiver usually user is no need to match again If need please follow up the following steps to match 1 Open the scann...

Page 8: ... mode and another one is one to two mode Please follow up the following steps to build four to one mode 1 Open the first scanner 2 According the above one on one pairing to set the scanner 3 Match successfully which mean the first scanner work under networking it is one to one mode 4 Open the second scanner same operation as above one on one pairing after match successfully they become two to one ...

Page 9: ... buzzer Di Di Di three ticking sounds which mean matching successfully if scanner buzzer Di Di Di Di Di Di six ticking sounds which mean failure 5 If match successfully one to two mode networking setting successfully 6 If fail to match please repeat above step 1 2 3 to reset Part Eleven Barcode For Common Function Setting One on One pairing after scanning this command the original matching mode is...

Page 10: ... Y C O C M D D E F A U L T Memory function enable for setting the scanner to record barcode data if fail to data transmission H Y C O C M D S T O R E Memory function disable for setting scanner no need to record barcode data if fail to data transmission during normal scanning also delete all the recorded data Please be attention If scanner has recorded barcode data be cautious of using this functi...

Page 11: ...on barcode type and parameters keep the same Furthermore if scanner has recorded barcode data the data will be deleted Part Twelve Default Parameters of Barcode Types EAN Decode OPEN EAN13 Check Code Output OPEN EAN8 Check Code Output OPEN Lead Code Output OPEN Complement Decode AUTO UPC Decode OPEN UPCA Check Code Output OPEN UPCE Check Code Output OPEN Lead Code Output OPEN CODE128 Decode OPEN R...

Page 12: ...ngth Max 50 Error Checking CLOSE Check Code Output OPEN GS1 Decode CLOSE ITF25 Decode OPEN Recognition Length Min 8 Recognition Length Max 50 Error Checking CLOSE Check Code Output OPEN INDUS25 Decode CLOSE Recognition Length Min 8 Recognition Length Max 50 IATA25 Decode CLOSE Recognition Length Min 8 Recognition Length Max 50 Error Checking CLOSE Check Code Output OPEN ...

Page 13: ...ength Min 8 Recognition Length Max 50 MSI Decode Close Recognition Length Min 8 Recognition Length Max 50 Error Checking CLOSE Check Code Output OPEN Part Thirteen Performance Parameter Functionality Item Performance Parameter Working Frequency 433MHz ISM Frequency Range Communication Distance Up to 200 Meters at open place Type of Illuminant 650nm Laser Use Type Hand held Scanning Method Manual I...

Page 14: ...AN8 EAN13 UPC_A UPC_E CODE128 C ODE39 CODE93 CODE11 GS1_DATABAR ITF25 INDUS25 IATA25 MATRIX25 CHI NESE25 CODABAR MSI All Standard One dimensional code Battery 3 7V 1000mAh Li ion Charge Time 2 5 Hours Scan Time 30 Hours Scan Current 85mA Standby Current 30mA Maximum Pitch Angles 60 Maximum Tilt Angles 45 Working Frequency 433MHz Communication Distance 200m Open Places Communication Interface USB O...

Page 15: ...er no reaction Scanner does not connect properly with power source Checkout system power source Check whether scanning button has already pressed or battery has used up or not Cannot start after pressing the scanner button Low Battery Restart after recharged Indicator light is off when scanner is recharging Plug of recharger is not connected with scanner recharging port Turn the plug of recharger ...

Page 16: ...r scanning Receiver does not connect with PC Check receiver and make it connected well with PC Receiver does not match successfully with scanner Check receiver to make it match successfully with scanner Transmission range is exceed effective range Make sure receiver and scanner are inside effective transmission range Scanner always cannot match successfully with receiver Wrong matching steps Follo...

Page 17: ...w material or production process our company can repair for free All the problem or damage that due to the behave which result from the operating not according to User s Manual install yourself dismantle yourself or misapplication our company provide the warranty maintenance but need proper service charges and parts cost Warranty Principle 1 Warranty period is one year 2 During warranty period in ...

Page 18: ...t not inside warranty period 6 User should pack the product that plan to send for repairing well our company suggest pack it by original packing carton We are not responsible for the damage that due to logistic 7 We are not responsible for the special accident or indirect losses of customers and distributors 8 Content is subject to change without prior notice 9 Regarding the related issues please ...

Page 19: ...setting barcode Enable of corresponding barcode type close means scan the setting barcode Disable of corresponding barcode type Because the setting barcode is CODE 128 so the CODE128 barcode can t be closed F N C 3 0 2 0 1 0 1 F N C 3 0 2 0 1 0 0 F N C 3 0 2 0 2 0 1 F N C 3 0 2 0 2 0 0 F N C 3 0 2 0 3 0 1 F N C 3 0 2 0 3 0 0 F N C 3 0 2 0 4 0 1 F N C 3 0 2 0 4 0 0 ...

Page 20: ... 1 F N C 3 0 2 0 5 0 0 F N C 3 0 2 0 6 0 1 F N C 3 0 2 0 6 0 0 F N C 3 0 2 0 7 0 1 F N C 3 0 2 0 7 0 0 F N C 3 0 2 0 8 0 1 F N C 3 0 2 0 8 0 0 F N C 3 0 2 0 9 0 1 F N C 3 0 2 0 9 0 0 F N C 3 0 2 1 0 0 1 F N C 3 0 2 1 0 0 0 ...

Page 21: ... to recognize random length The setting process is as following 1 Scan the maximum length setting barcode of corresponding barcode type 2 Scan digital barcode please see Digital barcode in page 29 scanning the digit Such as if need to input 15 then should first scan digital barcode 1 and then scan digital barcode 5 3 Scan setting barcode confirm check page 30 If do not confirm then all the previou...

Page 22: ... 0 F N C 3 0 3 0 3 0 1 F N C 3 0 3 0 4 0 0 F N C 3 0 3 0 4 0 1 F N C 3 0 3 0 5 0 0 F N C 3 0 3 0 5 0 1 F N C 3 0 3 0 6 0 0 F N C 3 0 3 0 6 0 1 F N C 3 0 3 0 8 0 0 F N C 3 0 3 0 8 0 1 F N C 3 0 3 0 9 0 0 F N C 3 0 3 0 9 0 1 ...

Page 23: ...C 3 0 3 1 4 0 1 4 Check Code Output Switch Setting These code is used to setting whether output the check code of corresponding barcode type User can open or close the check codes output of designated barcode type Open means scan setting barcode check code output enable of corresponding barcode type close means scan setting barcode check code output Disable of corresponding barcode type ...

Page 24: ... 1 F N C 3 0 4 0 1 0 0 F N C 3 0 4 0 1 1 1 F N C 3 0 4 0 1 1 0 F N C 3 0 4 0 2 0 1 F N C 3 0 4 0 2 0 0 F N C 3 0 4 0 2 1 1 F N C 3 0 4 0 2 1 0 F N C 3 0 4 0 4 0 1 F N C 3 0 4 0 4 0 0 F N C 3 0 4 0 6 0 1 F N C 3 0 4 0 6 0 0 ...

Page 25: ...arcode characters if calibrate error then it would be considered as misrecognition cannot output barcode User can open or close the error checking of a barcode by manual according to user s needs Scan the setting barcode Error checking Enable of corresponding barcode type can open this function scanning the setting barcode Error checking Disable of corresponding barcode type can close Warning Beca...

Page 26: ... 0 4 0 0 F N C 3 0 5 0 6 0 1 F N C 3 0 5 0 6 0 0 F N C 3 0 5 0 8 0 1 F N C 3 0 5 0 8 0 0 F N C 3 0 5 1 0 0 1 F N C 3 0 5 1 0 0 0 F N C 3 0 5 1 1 0 1 F N C 3 0 5 1 1 0 0 F N C 3 0 5 1 4 0 1 F N C 3 0 5 1 4 0 0 6 Lead Code Output Setting ...

Page 27: ...fill code outputting of a barcode by manual according to user s need Open means scan the barcode Fill code outputting enable of corresponding barcode close means scan the barcode Fill code outputting Disable of corresponding barcode Open When the complement code cannot be recognized correctly it will be considered as wrong recognition would not output barcode when the complement code can be recogn...

Page 28: ...ch setting by manual according to user s requirement Open recognize barcode CODE39 of FULL ASCII CODE Close only recognize normal barcode CODE 39 F N C 3 0 8 0 4 0 1 F N C 3 0 8 0 4 0 0 9 Only Digit Recognition of Barcode Switch Setting In order to increase the recorded number of barcode user can set the mode to be Only Digit Recognition of Barcode which could double the recorded number Recognitio...

Page 29: ... bar codes when record already 166 bar codes scanner head will close When scan HYCOCMD NUMBAR only recognize the digits of barcode ignore letters At that time if barcode less than or equal to 30 characters including Enter or Tab character the maximum recorded number is 512 bar codes When record reach 500 bar codes scanner head will close More than 30 and less than or equal to 60 characters includi...

Page 30: ...Cancel barcode is the Auxiliary barcode of setting barcode F N C 3 1 2 0 1 0 1 F N C 3 1 2 0 1 0 0 12 Power Setting This is advanced setting users can set the corresponding power of barcode scanner according to the actual application Users should use this setting prudently before setting please consult distributor or our factory Power Grade Barcode Transmission Range ...

Page 31: ... Y C O C M D P W R 1 7 160 Meters Grade 6 H Y C O C M D P W R 1 4 120 Meters Grade 5 H Y C O C M D P W R 1 1 100 Meters Grade 4 H Y C O C M D P W R 0 8 80 Meters Grade 3 H Y C O C M D P W R 0 5 60 Meters Grade 2 H Y C O C M D P W R 0 2 40 Meters Grade 1 H Y C O C M D P W R 0 1 20 Meters ...

Page 32: ...l serial port driver after changing into serial mode If do not install driver then every time connecting to USB will get popup installation indication also cannot change back to keyboard mode anymore and the read barcode data can t be transmitted ...

Reviews: