background image

 

Summary of Contents for CLV622

Page 1: ......

Page 2: ...rl Valentin GmbH Due to the constant further development of our devices discrepancies between manual and device can occur Please check www carl valentin de for the latest update Trademarks All named brands or trademarks are registered brands or registered trademarks of their respective owners and may not be separately labelled It must not be concluded from the missing labelling that it is not a re...

Page 3: ...1 4 1 1 Reading Configuration 12 4 1 2 Code Configuration 13 4 1 3 Data Processing 13 4 1 4 Network Interfaces IOs 16 4 2 Saving the Settings in the Scanner 17 4 3 Loading a Configuration File 17 5 Function Menu Scanner 19 5 1 Scanner Mode 19 5 2 Scanner Type 20 5 3 Scanner Setup 20 5 4 Scan Offset 20 5 5 Scan Length 21 5 6 Scan Mode 21 5 7 Scan Delay 22 5 8 Scan Timeout 22 5 9 Interface Parameter...

Page 4: ...Table of Contents Scanner SICK CLV622 4 Operating Manual 08 19 ...

Page 5: ...ediately 1 1 Environmentally Friendly Disposal Manufacturers of B2B equipment are obliged to take back and dispose of old equipment that was manufactured after 13 August 2005 As a principle this old equipment may not be delivered to communal collecting points It may only be organised used and disposed of by the manufacturer Valentin products accordingly labelled can therefore be returned to Carl V...

Page 6: ...ons The SMART620 Code reconstruction allows accurate detection of damaged dirty and partially dirty bar codes The data can be transferred to the controller in the desired format This results in less programming effort Even at high conveyor speeds the CLV622 can provide real time code identification The compact desig and simple operation facilitate the installation in space critical situations ...

Page 7: ... voltage 10 V DC 30 V DC when connecting to the printer 24 V DC Power consumption 4 5 W Housing Aluminum die cast Housing color Light blue RAL 5012 Front screen Glass Enclosure rating IP65 DIN 40 050 Protection class III VDE 0106 IEC 1010 1 Weight 225 g with connecting cable Dimensions L x W x H 61 mm x 66 mm x 38 mm MTBF 40 000 h Performance Readable code structures 1D Bar code types All current ...

Page 8: ...ult laser cata CAN LNK TX Acoustic indicators Beeper buzzer can be switched off can be allocated as a result indication function Configuration software SOPAS ET Ambient data Electromagnetic compatibility EMV EN 61000 6 3 2001 10 EN 61000 6 2 2005 Vibration resistance EN 60068 2 6 1995 Shock resistance EN 60068 2 27 1993 Ambient operating temperature 0 C 40 C Storage temperature 20 C 70 C Permissib...

Page 9: ...he option scanner disconnect the label printer from the mains supply and wait for a moment until the power supply unit has discharged Figure 2 1 Open the right printer cover 2 Remove the lower front panel 3 Fasten the scanner bracket B with the fixing screws C at the printer A It is important to pay attention to the plug connection 4 Insert the label material as described in the operating manual A...

Page 10: ...Installation of Scanner Bracket Scanner SICK CLV622 10 Operating Manual 08 19 ...

Page 11: ...er bracket Alternatively the scanner can also be connected to an optional connection module SICK CDB620 for the configuration and the connection to the PC can be made from there 4 1 Settings of the Scanner Software After starting the software SOPAS ET it searches for the connected scanner and displays it on the user interface Figure 3 By double clicking on the scanner symbol or by clicking Open de...

Page 12: ... changed there 4 1 1 Reading Configuration Various settings regarding the signal to start the scanner can be made Figure 5 Do not change the setting Start by User defined command because the scanner is to be controlled by the printer which sends the start command K and the stop command I Figure 6 Normally no settings are necessary Object trigger control Illumination control ...

Page 13: ...ng Manual 13 Figure 7 Normally no settings are necessary 4 1 2 Code Configuration Settings regarding the codes to be scanned can be made Figure 8 4 1 3 Data Processing Settings for the data processing can be adjusted here Figure 9 PowerSave control ...

Page 14: ... for the data transmission point as soon as possible and the output condition Good Read should not be changed Figure 11 Normally no settings are necessary At print start the printer sends the number of codes to be scanned min max to the scanner Figure 12 Normally no settings are necessary Output control Evaluation conditions Matchcode Teach In ...

Page 15: ... 05 19 Operating Manual 15 Figure 13 Normally no settings are necessary Figure 14 No changes should be made here othewise the communication between printer and scanner may not work Filter sorter for the output formatting Output format ...

Page 16: ...Serial Host is used as connection between the scanner and printer If the interface parameters baud rate etc are changed they must be adjusted accordingly in the function menu Scanner of the printer Figure 16 No settings are necessary as the scanner is not controlled via the digital inputs Serial Digitale Eingänge ...

Page 17: ... To save the settings in the scanner in the menu under the device name CLV62x select the function Parameter Save permanent This can also be done with clicking on the symbol 4 3 Loading a Configuration File To load an existing configuration file from the PC the function Device Import SDV file must be selected After selecting the file name sdv the parameters are loaded and can be saved in the scanne...

Page 18: ......

Page 19: ... can read the printed bar codes This mode is to use if the bar code is available as graphic e g printing with printer driver In this case the printer cannot recognize that a bar code is placed onto the label Indication of number of successive non readables i e when the printer indicates an error message Value range 0 9 1 the printer stops at the first label which cannot be red from the 1 scanner a...

Page 20: ...ase a bar code is read then the read data is indicated in the display and the scanner is immediately again set to on Is the scanner in the correct position it starts to flicker Is the scanner not in the correct position then it is set to on as long as again a bar code is read The scanner is to position in the way that at feeding labels of 1 the bar code is directly read at the printhead 5 4 Scan O...

Page 21: ... Scan Mode With this parameter can be adjusted at which time the scanning of the bar code is to be effected during printing or after printing While printing The scanning of bar code is effected while the label is printed By means of the parameter number of feeding labels can be defined which label should be scanned With the parameters Scan offset and Scan length the scan sector can be specified Af...

Page 22: ...f the parameter scan timeout is set to 0 the printer waits until the bar code could be read If the bar code is not read withing the fixed time the printer switches Off the scanner again non readable When reaching the fixed number of consecutive non readable an error message appears at the display This parameter is not relevant in scan mode while print 5 9 Interface Parameter Set the parameter of s...

Page 23: ... N 5 6 bad readings N 6 7 bad readings N 7 8 bad readings N 8 9 bad readings Number of consecutive bad readings after which an error message is displayed With 0 NoReads no error message occurs i e the print procedure is not interrupted Only a warning will be shown on the display F 0 No label feed FeedLabel F 1 Feed by 1 label F 2 Feed by 2 labels F 3 Feed by 3 labels F 4 Feed by 4 labels F 5 Feed ...

Page 24: ...fter printing Enquire scan mode SOH F C D M C w p p p p p p p p ETB Answer SOH A N p p p p p p p p ETB N current scan mode Set scan delay scanning after printing SOH F C D M D r N N N N ETB N Scan delay in ms 0 9990 Enquire scan delay SOH F C D M D w p p p p p p p p ETB Answer SOH A N N N N p p p p p p p p ETB N Current scan delay in ms Set scan timeout scanning after printing SOH F C D M E r N N ...

Page 25: ... has to provide the possibility to define the order of bar code data to scan multiple codes onto a label Because of this reason it is necessary to define the bar code data in the text statements as scanner variable The text statement has the following structure Scanner variable SOH BM n S V a f text data ETB SV Identification of scanner variable a Field active 0 not active 1 active i e the code is...

Page 26: ...Parameter Sets for Scanner Mode Scanner SICK CLV622 26 Operating Manual 08 19 ...

Page 27: ...too high Increase the contrast Clean the printhead or exchange if necessary Reduce the print speed 70 Scanner data Scanned data does not correspond to the data which is to print Exchange printhead 94 Scanner Timeout The scanner could not read the bar code within the set timeout time Defective printhead Wrinkles in the transfer ribbon Scanner wrong positioned Timeout time too short Check the printh...

Page 28: ...Error Messages Scanner SICK CLV622 28 Operating Manual 08 19 ...

Page 29: ... friendly disposal 5 error messages 27 F function menu scanner interface parameter 22 scan delay 22 scan length 21 scan mode 21 scan offset 20 scan timeout 22 scanner mode 19 scanner setup 20 type 20 G general notes 5 I installation Spectra II 9 P parameter sets scanner 23 24 25 scanner variable 25 product description 6 T technical data 7 8 ...